Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractGenetic analysis reveals three novel QTLs underpinning a butterfly egg-induced hypersensitive response-like cell death in Brassica rapa    Next AbstractEcosystem consequences of enhanced solar ultraviolet radiation: secondary plant metabolites as mediators of multiple trophic interactions in terrestrial plant communities »

J Clin Med


Title:Improved Non-Invasive Diagnosis of Bladder Cancer with an Electronic Nose: A Large Pilot Study
Author(s):Bassi P; Di Gianfrancesco L; Salmaso L; Ragonese M; Palermo G; Sacco E; Giancristofaro RA; Ceccato R; Racioppi M;
Address:"Department of Urology, Fondazione Policlinico Universitario 'Agostino Gemelli' IRCCS di Roma, Universita Cattolica del Sacro Cuore di Roma, Largo Agostino Gemelli, 8, 00168 Rome, Italy. Department of Management and Engineering, Universita di Padova, 35122 Padova, Italy"
Journal Title:J Clin Med
Year:2021
Volume:20211027
Issue:21
Page Number: -
DOI: 10.3390/jcm10214984
ISSN/ISBN:2077-0383 (Print) 2077-0383 (Electronic) 2077-0383 (Linking)
Abstract:"BACKGROUND: Bladder cancer (BCa) emits specific volatile organic compounds (VOCs) in the urine headspace that can be detected by an electronic nose. The diagnostic performance of an electronic nose in detecting BCa was investigated in a pilot study. METHODS: A prospective, single-center, controlled, non-randomized, phase 2 study was carried out on 198 consecutive subjects (102 with proven BCa, 96 controls). Urine samples were evaluated with an electronic nose provided with 32 volatile gas analyzer sensors. The tests were repeated at least two times per sample. Accuracy, sensitivity, specificity, and variability were evaluated using mainly the non-parametric combination method, permutation tests, and discriminant analysis classification. RESULTS: Statistically significant differences between BCa patients and controls were reported by 28 (87.5%) of the 32 sensors. The overall discriminatory power, sensitivity, and specificity were 78.8%, 74.1%, and 76%, respectively; 13/96 (13.5%) controls and 29/102 (28.4%) BCa patients were misclassified as false positive and false negative, respectively. Where the most efficient sensors were selected, the sensitivity and specificity increased up to 91.1% (72.5-100) and 89.1% (81-95.8), respectively. None of the tumor characteristics represented independent predictors of device responsiveness. CONCLUSIONS: The electronic nose might represent a potentially reliable, quick, accurate, and cost-effective tool for non-invasive BCa diagnosis"
Keywords:bladder cancer electronic nose non-invasive diagnosis volatile organic compounds;
Notes:"PubMed-not-MEDLINEBassi, PierFrancesco Di Gianfrancesco, Luca Salmaso, Luigi Ragonese, Mauro Palermo, Giuseppe Sacco, Emilio Giancristofaro, Rosa Arboretti Ceccato, Riccardo Racioppi, Marco eng Switzerland 2021/11/14 J Clin Med. 2021 Oct 27; 10(21):4984. doi: 10.3390/jcm10214984"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024