Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractCritical components of odors in evaluating the performance of food waste composting plants    Next AbstractColorimetric Signal Readout for the Detection of Volatile Organic Compounds Using a Printable Glass-Based Dielectric Barrier Discharge-Type Helium Plasma Detector »

Sci Total Environ


Title:Method development for determining the malodor source and pollution in industrial park
Author(s):Mao IF; Chen MR; Wang L; Chen ML; Lai SC; Tsai CJ;
Address:"Department of Occupational Safety and Health, Chung Shan Medical University, No. 110, Sec. 1, Jianguo N.Rd., Taichung, Taiwan"
Journal Title:Sci Total Environ
Year:2012
Volume:20120901
Issue:
Page Number:270 - 275
DOI: 10.1016/j.scitotenv.2012.08.056
ISSN/ISBN:1879-1026 (Electronic) 0048-9697 (Linking)
Abstract:"Malodor pollution emitted from industrial park has become an important environmental issue. However, the difficulty in investigating malodor pollution is in determining the malodor source. The objective of this study was to develop a model for determining the malodor source and pollution in industrial park, via multiple time and site measurements of odor intensity and air pollutants, together with wind direction in different seasons, and the critical environmental factors could be also identified by correlating the odor intensities with meteorological conditions and the concentrations of air pollutants. A high-malodor-polluted industrial park involving metal and petrochemistry processing industries was selected as the study subject, and sampling was performed close to residential districts. Nine sites were selected as sampling points by a chessboard design, with each site measured for 5 days in fall and spring, respectively. Odor intensity (ratings 0-5) and environmental factors, including meteorological condition, PM(10), PM(2.5), total volatile organic compounds (TVOCs), ammonia and reduced sulfides, were evaluated six times daily. The results indicated that the incidences of odor ratings 1-5 were 71.9% and 81.0% in two seasons in the sampling area, and an open ditch for collecting industrial wastewater for feeding to the wastewater treatment plant was identified as the main odor source. Multiple regression analysis showed that the odor rating significantly correlated with TVOC concentration and wind speed (P<0.05); odor intensity increased by 0.001 units on the rating scale for each 1 ppb increase in TVOCs, and decreased by 0.154 units for each 1m/s increase in wind speed. This study developed a method to explore malodor pollution in industrial park, providing a novel thinking to understand and resolve malodor problems"
Keywords:"*Air Pollutants, Occupational/analysis Air Pollution/analysis Ammonia/analysis Environmental Monitoring/methods Humans *Metallurgy Models, Chemical Odorants/*analysis Particulate Matter/analysis Petroleum/*analysis Regression Analysis Seasons Sulfides/ana;"
Notes:"MedlineMao, I-Fang Chen, Mei-Ru Wang, Lee Chen, Mei-Lien Lai, Sin-Chen Tsai, Chung-Jung eng Research Support, Non-U.S. Gov't Netherlands 2012/09/05 Sci Total Environ. 2012 Oct 15; 437:270-5. doi: 10.1016/j.scitotenv.2012.08.056. Epub 2012 Sep 1"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 06-11-2024