Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractCounter-perfume: using pheromones to prevent female remating    Next AbstractThe nature of the gregarizing signal responsible for maternal transfer of phase to the offspring in the desert locust Schistocerca gregaria »

J Toxicol Environ Health A


Title:Fungal and microbial volatile organic compounds exposure assessment in a waste sorting plant
Author(s):Malta-Vacas J; Viegas S; Sabino R; Viegas C;
Address:"Higher School of Health Technology of Lisbon (ESTESL)/Polytechnic Institute of Lisbon (IPL), Lisbon, Portugal"
Journal Title:J Toxicol Environ Health A
Year:2012
Volume:75
Issue:22-23
Page Number:1410 - 1417
DOI: 10.1080/15287394.2012.721175
ISSN/ISBN:1528-7394 (Print) 0098-4108 (Linking)
Abstract:"In the management of solid waste, pollutants over a wide range are released with different routes of exposure for workers. The potential for synergism among the pollutants raises concerns about potential adverse health effects, and there are still many uncertainties involved in exposure assessment. In this study, conventional (culture-based) and molecular real-time polymerase chain reaction (RTPCR) methodologies were used to assess fungal air contamination in a waste-sorting plant which focused on the presence of three potential pathogenic/toxigenic fungal species: Aspergillus flavus, A. fumigatus, and Stachybotrys chartarum. In addition, microbial volatile organic compounds (MVOC) were measured by photoionization detection. For all analysis, samplings were performed at five different workstations inside the facilities and also outdoors as a reference. Penicillium sp. were the most common species found at all plant locations. Pathogenic/toxigenic species (A. fumigatus and S. chartarum) were detected at two different workstations by RTPCR but not by culture-based techniques. MVOC concentration indoors ranged between 0 and 8.9 ppm (average 5.3 +/- 3.16 ppm). Our results illustrated the advantage of combining both conventional and molecular methodologies in fungal exposure assessment. Together with MVOC analyses in indoor air, data obtained allow for a more precise evaluation of potential health risks associated with bioaerosol exposure. Consequently, with this knowledge, strategies may be developed for effective protection of the workers"
Keywords:"Air Microbiology *Air Pollutants, Occupational/metabolism/toxicity Air Pollution, Indoor/adverse effects Aspergillus/classification/growth & development/isolation & purification/metabolism Carcinogens, Environmental/*administration & dosage/metabolism/tox;"
Notes:"MedlineMalta-Vacas, J Viegas, S Sabino, R Viegas, C eng Comparative Study Research Support, Non-U.S. Gov't England 2012/10/26 J Toxicol Environ Health A. 2012; 75(22-23):1410-7. doi: 10.1080/15287394.2012.721175"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024