Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract[Characteristics of changes of personal odor after experimental bone marrow transplantation]    Next AbstractKey Design Elements of Building Pressure Cycling for Evaluating Vapor Intrusion-A Literature Review »

Ground Water Monit Remediat


Title:Observation of Conditions Preceding Peak Indoor Air Volatile Org Compound Concentrations in Vapor Intrusion Studies
Author(s):Lutes C; Holton C; Schumacher B; Zimmerman J; Kondash A; Truesdale R;
Address:"Jacobs, Raleigh, NC. Geosyntec Consultants Inc., Denver, CO. U.S. Environmental Protection Agency, Athens, GA. U.S. Environmental Protection Agency, Research Triangle Park, NC. RTI International, Research Triangle Park, NC"
Journal Title:Ground Water Monit Remediat
Year:2021
Volume:41
Issue:2
Page Number:99 - 111
DOI: 10.1111/gwmr.12452
ISSN/ISBN:1069-3629 (Print) 1745-6592 (Electronic) 1069-3629 (Linking)
Abstract:"Temporal and spatial variability of indoor air volatile organic compound (VOC) concentrations can complicate vapor intrusion (VI) assessment and decision-making. Indicators and tracers (I&T) of VI, such as differential temperature, differential pressure, and indoor radon concentration, are low-cost lines of evidence to support sampling scheduling and interpretation of indoor air VOC sampling results. This study compares peak indoor air chlorinated VOC concentrations and I&T conditions before and during those peak events at five VI sites. The sites differ geographically and in their VI conceptual site models (CSM). Relative to site-specific baseline values, the results show that cold or falling outdoor temperatures, rising cross slab differential pressures, and increasing indoor radon concentrations can predict peak VOC concentrations. However, cold outdoor air temperature was not useful at one site where elevated shallow soil temperature was a better predictor. Correlations of peak VOC concentrations to elevated or rising barometric pressure and low wind speed were also observed with some exceptions. This study shows how the independent variables that control or predict peak indoor air VOC concentrations are specific to building types, climates, and VI CSMs. More I&T measurements at VI sites are needed to identify scenario-specific baseline and peak related I&T conditions to improve decision-making"
Keywords:
Notes:"PubMed-not-MEDLINELutes, Chris Holton, Chase Schumacher, Brian Zimmerman, John Kondash, Andrew Truesdale, Robert eng EPA999999/ImEPA/Intramural EPA/ 2021/08/03 Ground Water Monit Remediat. 2021 May 21; 41(2):99-111. doi: 10.1111/gwmr.12452"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024