Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractNon-volatile floral oils of Diascia spp. (Scrophulariaceae)    Next AbstractAn assessment of correlations between chlorinated VOC concentrations in tree tissue and groundwater for phytoscreening applications »

J Phys Chem B


Title:Detection of volatile organic compounds using porphyrin derivatives
Author(s):Dunbar AD; Brittle S; Richardson TH; Hutchinson J; Hunter CA;
Address:"Department of Chemical and Biological Engineering, University of Sheffield, Sir Robert Hadfield Building, Mappin Street, Sheffield S1 3JD, UK. a.dunbar@sheffield.ac.uk"
Journal Title:J Phys Chem B
Year:2010
Volume:114
Issue:36
Page Number:11697 - 11702
DOI: 10.1021/jp102755h
ISSN/ISBN:1520-5207 (Electronic) 1520-5207 (Linking)
Abstract:"Seven different porphyrin compounds have been investigated as colorimetric gas sensors for a wide range of volatile organic compounds. The porphyrins examined were the free base and Mg, Sn, Zn, Au, Co, and Mn derivatives of 5,10,15,20-tetrakis[3,4-bis(2-ethylhexyloxy)phenyl]-21H,23H-porphine. Chloroform solutions of these materials were prepared and changes in their absorption spectra induced by exposure to various organic compounds measured. The porphyrins that showed strong responses in solution were selected, and Langmuir-Blodgett films were prepared and exposed to the corresponding analytes. This was done to determine whether they are useful materials for solid state thin film colorimetric vapor sensors. Porphyrins that readily coordinate extra ligands are shown to be suitable materials for colorimetric volatile organic compound detectors. However, porphyrins that already have bound axial ligands when synthesized only show a sensor response to those analytes that can substitute these axial ligands. The Co porphyrin displays a considerably larger response than the other porphyrins investigated which is attributed to a switch between Co(II) and Co(III) resulting in a large spectral change"
Keywords:
Notes:"PubMed-not-MEDLINEDunbar, A D F Brittle, S Richardson, T H Hutchinson, J Hunter, C A eng 2010/08/26 J Phys Chem B. 2010 Sep 16; 114(36):11697-702. doi: 10.1021/jp102755h"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 23-11-2024