« Previous AbstractMeasuring concentrations of volatile organic compounds in vinyl flooring    Next AbstractCommunity composition and phenology of native Siricidae (Hymenoptera) attracted to semiochemicals in Minnesota »

Indoor Air


Title:Diffusion-controlled reference material for VOC emissions testing: proof of concept
Author(s):Cox SS; Liu Z; Little JC; Howard-Reed C; Nabinger SJ; Persily A;
Address:"Department of Civil and Environmental Engineering, Virginia Tech, Durham Hall, Blacksburg, VA 24061-0246, USA"
Journal Title:Indoor Air
Year:2010
Volume:20100623
Issue:5
Page Number:424 - 433
DOI: 10.1111/j.1600-0668.2010.00666.x
ISSN/ISBN:1600-0668 (Electronic) 0905-6947 (Linking)
Abstract:"Because of concerns about indoor air quality, there is growing awareness of the need to reduce the rate at which indoor materials and products emit volatile organic compounds (VOCs). To meet consumer demand for low emitting products, manufacturers are increasingly submitting materials to independent laboratories for emissions testing. However, the same product tested by different laboratories can result in very different emissions profiles because of a general lack of test validation procedures. There is a need for a reference material that can be used as a known emissions source and that will have the same emission rate when tested by different laboratories under the same conditions. A reference material was created by loading toluene into a polymethyl pentene film. A fundamental emissions model was used to predict the toluene emissions profile. Measured VOC emissions profiles using small-chamber emissions tests compared reasonably well to the emissions profile predicted using the emissions model, demonstrating the feasibility of the proposed approach to create a diffusion-controlled reference material. PRACTICAL IMPLICATIONS: To calibrate emissions test chambers and improve the reproducibility of VOC emission measurements among different laboratories, a reference material has been created using a polymer film loaded with a representative VOC. Initial results show that the film's VOC emission profile measured in a conventional test chamber compares well to predictions based on independently determined material/chemical properties and a fundamental emissions model. The use of such reference materials has the potential to build consensus and confidence in emissions testing as well as 'level the playing field' for product testing laboratories and manufacturers"
Keywords:"Air Pollution, Indoor/analysis Chemistry Techniques, Analytical/*standards Diffusion of Innovation Laboratories Models, Chemical Reference Values Toluene/*analysis/chemistry Volatile Organic Compounds/*analysis/chemistry;"
Notes:"MedlineCox, S S Liu, Z Little, J C Howard-Reed, C Nabinger, S J Persily, A eng Evaluation Study Research Support, Non-U.S. Gov't England 2010/06/29 Indoor Air. 2010 Oct; 20(5):424-33. doi: 10.1111/j.1600-0668.2010.00666.x. Epub 2010 Jun 23"

 