Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractTuning the olefin-VOCs epoxidation performance of ceria by mechanochemical loading of coinage metal    Next AbstractSecreted expression of human lysozyme in the yeast Pichia pastoris under the direction of the signal peptide from human serum albumin »

J Chromatogr A


Title:On-site calibration method based on stepwise solid-phase microextraction
Author(s):Xiong G; Chen Y; Pawliszyn J;
Address:"Faculty of Science, Department of Chemistry, University of Waterloo, 220 University Avenue West, Waterloo, ON N2L 3G1, Canada"
Journal Title:J Chromatogr A
Year:2003
Volume:999
Issue:1-Feb
Page Number:43 - 50
DOI: 10.1016/s0021-9673(03)00602-2
ISSN/ISBN:0021-9673 (Print) 0021-9673 (Linking)
Abstract:"A stepwise solid-phase microextraction (SPME) method was developed for on-site calibration of SPME for volatile organic compounds analysis. In this approach, a 75-microm Carboxen-polydimethylsiloxane coated fibre was loaded with a prior to exposure to samples of interest Extraction time for the target analytes can be controlled independently from that of the standard, and the response factors for the target analytes can be adjusted accordingly. A good reproducibility of the response factors for BTEXs (benzene, toluene, ethylbenzene and xylenes) was obtained with stepwise SPME. Satisfactory results were obtained by using this method for quantitative analysis of BTEXs in the air of a gas station when tetrachloroethylene was used as a standard. The introduction of standard via the stepwise SPME procedure makes SPME more useful in field applications. It can be used to detect leaks, contaminations and losses from loading of a standard onto a fibre to introduction of the fibre to an analytical instrument. However, this method cannot be used for compensation of sample matrix effects"
Keywords:Benzene/*analysis Benzene Derivatives/*analysis *Calibration Reference Standards Toluene/*analysis Xylenes/*analysis;
Notes:"MedlineXiong, Guohua Chen, Yong Pawliszyn, Janusz eng Research Support, Non-U.S. Gov't Netherlands 2003/07/30 J Chromatogr A. 2003 May 30; 999(1-2):43-50. doi: 10.1016/s0021-9673(03)00602-2"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 22-11-2024