Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Plant Volatilome in Greece: a Review on the Properties, Prospects, and Chemogeography"    Next AbstractA small subsurface ion mobility spectrometer sensor for detecting environmental soil-gas contaminants »

Appl Radiat Isot


Title:Rapid screening of 2-[18F]-fluoro-2-deoxy-D-glucose infusions for volatile organic compound contaminants by solid phase microextraction with gas chromatography-selective ion monitoring mass spectrometry (SPME-GC-SIMMS)
Author(s):Kanu AB; Dixon M; Zu YY; Bailey J; Gillies JM; Zweit J; Thomas CL;
Address:"Department of Instrumentation and Analytical Science, UMIST, Manchester, UK"
Journal Title:Appl Radiat Isot
Year:2003
Volume:58
Issue:2
Page Number:193 - 200
DOI: 10.1016/s0969-8043(02)00293-2
ISSN/ISBN:0969-8043 (Print) 0969-8043 (Linking)
Abstract:"A method compatible with radioactive samples, capable of detecting trace volatile components in a sample volume of ca. 1cm(3) of 2-[18F]-fluoro-2-deoxy-D-glucose solution is described. The approach, based on solid phase micro-extraction gas chromatography-mass spectrometry with a carboxen/polydimethylsiloxane based fibre, was optimised with respect to extraction time (10 min), extraction temperature (60 degrees C) and phase volume ratio (1). The analysis time, including extraction, was less than 20 min with linear responses for acetonitrile and ethanol over the ranges: 0.09-80 microg cm(-3) (22 degrees C, acetonitrile) and 0.78-79 microg cm(-3) (22 degrees C, ethanol). The detection limits were estimated to be ca. 0.78 microg cm(-3) for ethanol and 0.09 microg cm(-3) for acetonitrile. Stability studies indicated analyte losses of up to 75% over 24h and analysis of aged 2-[18F]FDG samples showed that levels of ethanol and acetonitrile were not less than 100 microg cm(-3), indicative of levels substantially greater than this in the original infusions given to human subjects"
Keywords:Calibration Drug Contamination/*prevention & control Fluorodeoxyglucose F18/*analysis/standards Gas Chromatography-Mass Spectrometry/*methods Organic Chemicals/analysis;
Notes:"MedlineKanu, A B Dixon, M Zu, Y Yin Bailey, J Gillies, J M Zweit, J Thomas, C L P eng Evaluation Study Research Support, Non-U.S. Gov't England 2003/02/08 Appl Radiat Isot. 2003 Feb; 58(2):193-200. doi: 10.1016/s0969-8043(02)00293-2"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 29-12-2024