Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Sex-specific mediation of foraging in the shore crab, Carcinus maenas"    Next AbstractRepellent properties of the host compound 4-allylanisole to the southern pine beetle »

Talanta


Title:Validation of thermodesorption method for analysis of semi-volatile organic compounds adsorbed on wafer surface
Author(s):Hayeck N; Gligorovski S; Poulet I; Wortham H;
Address:"Aix Marseille Universite, CNRS, LCE, FRE 3416, 3 Place Victor Hugo, Case 29, 13331 Marseille, France; TERA Environnement, Actipole Saint Charles, 131 Avenue de l??etoile, 13710 Fuveau, France. Electronic address: nathalie.hayeck@etu.univ-provence.fr. Aix Marseille Universite, CNRS, LCE, FRE 3416, 3 Place Victor Hugo, Case 29, 13331 Marseille, France. Electronic address: saso.gligorovski@univ-amu.fr. TERA Environnement, Actipole Saint Charles, 131 Avenue de l??etoile, 13710 Fuveau, France. Aix Marseille Universite, CNRS, LCE, FRE 3416, 3 Place Victor Hugo, Case 29, 13331 Marseille, France"
Journal Title:Talanta
Year:2014
Volume:20140130
Issue:
Page Number:63 - 69
DOI: 10.1016/j.talanta.2014.01.029
ISSN/ISBN:1873-3573 (Electronic) 0039-9140 (Linking)
Abstract:"To prevent the degradation of the device characteristics it is important to detect the organic contaminants adsorbed on the wafers. In this respect, a reliable qualitative and quantitative analytical method for analysis of semi-volatile organic compounds which can adsorb on wafer surfaces is of paramount importance. Here, we present a new analytical method based on Wafer Outgassing System (WOS) coupled to Automated Thermal Desorber-Gas chromatography-Mass spectrometry (ATD-GC-MS) to identify and quantify volatile and semi-volatile organic compounds from 6', 8' and 12' wafers. WOS technique allows the desorption of organic compounds from one side of the wafers. This method was tested on three important airborne contaminants in cleanroom i.e. tris-(2-chloroethyl) phosphate (TCEP), tris-(2-chloroisopropyl) phosphate (TCPP) and diethyl phthalate (DEP). In addition, we validated this method for the analysis and quantification of DEP, TCEP and TCPP and we estimated the backside organic contamination which may contribute to the front side of the contaminated wafers. We are demonstrating that WOS/ATD-GC-MS is a suitable and highly efficient technique for desorption and quantitative analysis of organophosphorous compounds and phthalate ester which could be found on the wafer surface"
Keywords:Adsorption Differential Thermal Analysis/methods *Gas Chromatography-Mass Spectrometry/methods Surface Properties Volatile Organic Compounds/*analysis Automated Thermal Desorber-Gas chromatography-Mass spectrometry Organophosphorus compounds Phthalate est;
Notes:"MedlineHayeck, Nathalie Gligorovski, Sasho Poulet, Irene Wortham, Henri eng Research Support, Non-U.S. Gov't Validation Study Netherlands 2014/04/12 Talanta. 2014 May; 122:63-9. doi: 10.1016/j.talanta.2014.01.029. Epub 2014 Jan 30"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024