Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractPassive indoor air sampling for consumer product chemicals: a field evaluation study    Next AbstractPhenology of Lacanobia subjuncta (Lepidoptera: Noctuidae) in Washington and Oregon apple orchards »

PLoS One


Title:Source apportionment and quantification of liquid and headspace leaks from closed system drug-transfer devices via Selected Ion Flow Tube Mass Spectrometry (SIFT-MS)
Author(s):Doepke A; Streicher RP;
Address:"Health Effects Laboratory Division (HELD), Centers for Disease Control and Prevention (CDC), National Institute for Occupational Safety and Health (NIOSH), Chemical and Biochemical Monitoring Branch (CBMB), Alice Hamilton Laboratories, Cincinnati, Ohio, United States of America"
Journal Title:PLoS One
Year:2021
Volume:20211104
Issue:11
Page Number:e0258425 -
DOI: 10.1371/journal.pone.0258425
ISSN/ISBN:1932-6203 (Electronic) 1932-6203 (Linking)
Abstract:"A system to differentiate and quantify liquid and headspace vapor leaks from closed system drug-transfer devices (CSTDs) is presented. CSTDs are designed to reduce or eliminate hazardous drug (HD) exposure risk when compounding and administering HDs. CSTDs may leak liquid, headspace, or a mixture of the two. The amount of HD contained in liquid and headspace leaks may be substantially different. Use of a test solution containing two VOCs with differences in ratios of VOC concentrations in the headspace and liquid enables source apportionment of leaked material. SIFT-MS was used to detect VOCs from liquid and headspace leaks in the vapor phase. Included in this report is a novel method to determine the origin and magnitude of leaks from CSTDs. A limit of leak detection of 24 muL of headspace vapor and 0.14 muL of test liquid were found using Selected Ion Flow Tube Mass Spectrometry (SIFT-MS)"
Keywords:Hazardous Substances/adverse effects/chemistry Humans Mass Spectrometry/instrumentation Pharmaceutical Preparations/*chemistry *Protective Devices Volatile Organic Compounds/*adverse effects;
Notes:"MedlineDoepke, Amos Streicher, Robert P eng 2021/11/05 PLoS One. 2021 Nov 4; 16(11):e0258425. doi: 10.1371/journal.pone.0258425. eCollection 2021"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 16-11-2024