Indoor Air


Title:State-of-the-art in the measurement of volatile organic compounds emitted from building products: results of European interlaboratory comparison
Author(s):De Bortoli M; Kephalopoulos S; Kirchner S; Schauenburg H; Vissers H;
Address:"European Commission, Joint Research Centre, Environment Institute, Ispra, Italy"
Journal Title:Indoor Air
Year:1999
Volume:9
Issue:2
Page Number:103 - 116
DOI: 10.1111/j.1600-0668.1999.t01-2-00005.x
ISSN/ISBN:0905-6947 (Print) 0905-6947 (Linking)
Abstract:"Eighteen laboratories from 10 European countries participated in a comparison organized as part of the VOCEM project, a 2.5-year research collaboration among 4 research institutes and 4 industrial companies. The scope of the project was to improve the procedure used to measure volatile organic compounds (VOC) emitted from building materials and products in small test chambers. The interlaboratory comparison included the GC-MS determination of 5 target compounds from carpet, 8 from polyvinyl chloride (PVC) cushion vinyl and 2 from paint; for the first time, chamber recovery (sinks), homogeneity of solid materials and possible contamination during transport were tested. The results show that the intralaboratory variance (random errors) is much smaller than the interlaboratory variance (systematic errors). Causes of the largest interlaboratory discrepancies were: (i) analytical errors; (ii) losses of the heaviest compounds due to sorption on the chamber walls; and (iii) non homogeneity of the materials. The output of this work concerns both the objective of labelling materials with regard to their VOC emissions and the pre-standard drafted by the European Commitee for Standardization (CEN) for this type of determination"
Keywords:"*Air Pollution, Indoor Europe Humans International Cooperation Materials Testing Organic Chemicals/*analysis Reference Values Volatilization;"
Notes:"MedlineDe Bortoli, M Kephalopoulos, S Kirchner, S Schauenburg, H Vissers, H eng Research Support, Non-U.S. Gov't Retracted Publication England 1999/07/03 Indoor Air. 1999 Jun; 9(2):103-16. doi: 10.1111/j.1600-0668.1999.t01-2-00005.x"

 