Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractVolatile Composition of Some Cultivated and Wild Culinary-Medicinal Mushrooms from Hungary    Next AbstractValorization of strawberry extrudate waste: Recovery of phenolic compounds by direct-hydrothermal treatment and subsequent methane production by mesophilic semi-continuous anaerobic digestion »

J Chromatogr A


Title:Standardization of chromatographic signals - Part I: Towards obtaining instrument-agnostic fingerprints in gas chromatography
Author(s):Cuadros-Rodriguez L; Ortega-Gavilan F; Martin-Torres S; Medina-Rodriguez S; Jimenez-Carvelo AM; Gonzalez-Casado A; Bagur-Gonzalez MG;
Address:"Department of Analytical Chemistry, Faculty of Science, University of Granada, C/ Fuentenueva s/n, E-18071, Granada, Spain. Department of Analytical Chemistry, Faculty of Science, University of Granada, C/ Fuentenueva s/n, E-18071, Granada, Spain. Electronic address: fog@ugr.es. By Techdesign S.L., C/ Tomas Edison 5, E-28500, Arganda del Rey, Madrid, Spain"
Journal Title:J Chromatogr A
Year:2021
Volume:20210209
Issue:
Page Number:461983 -
DOI: 10.1016/j.chroma.2021.461983
ISSN/ISBN:1873-3778 (Electronic) 0021-9673 (Linking)
Abstract:"One of the main causes for the sparse use of multivariate analytical methods in routine laboratory work is the dependency on the measuring instrument from which the analytical signal is acquired. This issue is especially critical in chromatographic equipment and results in limitations of their applicability. The solution to this problem is to obtain a standardized instrument-independent signal -or instrument-agnostic signal- regardless of the measuring instrument or of the state of the same instrument from which it has been acquired. The combined use of both internal and external standard series, allows us to have external and transferable references for the normalization of both the intensity and the position of each element of the data vector being arranged from the raw signal. From this information, a simple mathematical data treatment process is applied and instrument-agnostic signals can be secured. This paper describes and applies the proposed methodology to be followed for obtaining standardized instrumental fingerprints from two significant fractions of virgin olive oil (volatile organic compounds and triacylglycerols), obtained by gas chromatography coupled to mass spectrometry (GC-MS) and analysed with two temperature conditions (conventional and high-temperature, respectively). The results of both case studies show how the instrument-agnostic fingerprints obtained are coincidental, regardless of the state of the chromatographic system or the time of acquisition"
Keywords:"Chromatography, Gas/*methods/*standards Hot Temperature Olive Oil/chemistry Reference Standards Triglycerides/analysis Volatile Organic Compounds/analysis Empirical retention indices Instrument-agnostic chromatograms Intensity scaling Signal alignment Sta;"
Notes:"MedlineCuadros-Rodriguez, Luis Ortega-Gavilan, Fidel Martin-Torres, Sandra Medina-Rodriguez, Santiago Jimenez-Carvelo, Ana M Gonzalez-Casado, Antonio Bagur-Gonzalez, M Gracia eng Netherlands 2021/02/22 J Chromatogr A. 2021 Mar 29; 1641:461983. doi: 10.1016/j.chroma.2021.461983. Epub 2021 Feb 9"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024