Title: | Distributions of the particle/gas and dust/gas partition coefficients for seventy-two semi-volatile organic compounds in indoor environment |
Author(s): | Wei W; Mandin C; Blanchard O; Mercier F; Pelletier M; Le Bot B; Glorennec P; Ramalho O; |
Address: | "University of Paris-Est, Scientific and Technical Center for Building (CSTB), Health and Comfort Department, French Indoor Air Quality Observatory (OQAI), 84 Avenue Jean Jaures, Champs Sur Marne, 77447 Marne la Vallee Cedex 2, France. Electronic address: Wenjuan.WEI@cstb.fr. University of Paris-Est, Scientific and Technical Center for Building (CSTB), Health and Comfort Department, French Indoor Air Quality Observatory (OQAI), 84 Avenue Jean Jaures, Champs Sur Marne, 77447 Marne la Vallee Cedex 2, France; INSERM-U1085, Irset-Research Institute for Environmental and Occupational Health, Rennes, France; LERES-Environment and Health Research Laboratory (Irset and EHESP Technologic Platform), Rennes, France. EHESP-School of Public Health, Sorbonne Paris Cite, Rennes, France; INSERM-U1085, Irset-Research Institute for Environmental and Occupational Health, Rennes, France. EHESP-School of Public Health, Sorbonne Paris Cite, Rennes, France; INSERM-U1085, Irset-Research Institute for Environmental and Occupational Health, Rennes, France; LERES-Environment and Health Research Laboratory (Irset and EHESP Technologic Platform), Rennes, France. University of Paris-Est, Scientific and Technical Center for Building (CSTB), Health and Comfort Department, French Indoor Air Quality Observatory (OQAI), 84 Avenue Jean Jaures, Champs Sur Marne, 77447 Marne la Vallee Cedex 2, France" |
DOI: | 10.1016/j.chemosphere.2016.03.007 |
ISSN/ISBN: | 1879-1298 (Electronic) 0045-6535 (Linking) |
Abstract: | "Particle/gas and dust/gas partition coefficients (Kp and Kd) are two key parameters that address the partitioning of semi-volatile organic compounds (SVOCs) between gas-phase, airborne particles, and settled dust in indoor environment. A number of empirical equations to calculate the values of Kp and Kd have been reported in the literature. Therefore, the difficulty lies in the selection of a specific empirical equation in a given situation. In this study, we retrieved from the literature 38 empirical equations for calculating Kp and Kd values from the SVOC saturation vapor pressure and octanol/air partition coefficient. These values were calculated for 72 SVOCs: 9 phthalates, 9 polybrominated diphenyl ethers (PBDEs), 11 polychlorinated biphenyls (PCBs), 22 biocides, 14 polycyclic aromatic hydrocarbons (PAHs), 3 alkylphenols, 2 synthetic musks, tributylphosphate, and bisphenol A. The mean and median values of log10Kp or log10Kd for most SVOCs were of the same order of magnitude. The distribution of log10Kp values was fitted to either a normal distribution (for 27 SVOCs) or a log-normal distribution (for 45 SVOCs). This work provides a reference distribution of the log10Kp for 72 SVOCs, and its use may reduce the bias associated with the selection of a specific value or equation" |
Keywords: | "Air Pollution, Indoor/*analysis Environment Halogenated Diphenyl Ethers/*analysis Particulate Matter/*analysis Phthalic Acids/analysis Polychlorinated Biphenyls/*analysis Polycyclic Aromatic Hydrocarbons/*analysis Volatile Organic Compounds/*analysis Airb;" |
Notes: | "MedlineWei, Wenjuan Mandin, Corinne Blanchard, Olivier Mercier, Fabien Pelletier, Maud Le Bot, Barbara Glorennec, Philippe Ramalho, Olivier eng Research Support, Non-U.S. Gov't England 2016/03/28 Chemosphere. 2016 Jun; 153:212-9. doi: 10.1016/j.chemosphere.2016.03.007. Epub 2016 Mar 25" |