Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractCoupling of comprehensive two-dimensional gas chromatography with quadrupole mass spectrometry: application to the identification of atmospheric volatile organic compounds    Next AbstractFunctionalization of Carbonaceous Nanodots from Mn(II) -Coordinating Functional Knots »

Luminescence


Title:Development of a cataluminescence sensor for detecting benzene based on magnesium silicate hollow spheres
Author(s):Wang Y; Li B; Wang Q; Shou Z;
Address:"Qianjiang College, Hangzhou Normal University, Hangzhou, 310016, People's Republic of China. School of Information Engineering, East China Jiaotong University, Nanchang, 330013, People's Republic of China. School of Aeronautics and Astronautics, Zhejiang University, Hangzhou, 310027, People's Republic of China"
Journal Title:Luminescence
Year:2015
Volume:20141028
Issue:5
Page Number:619 - 624
DOI: 10.1002/bio.2795
ISSN/ISBN:1522-7243 (Electronic) 1522-7235 (Linking)
Abstract:"A novel and sensitive gas sensor was developed for the determination of benzene based on its cataluminescence (CTL) by oxidation in air on the surface of hollow magnesium silicate spheres. Luminescence characteristics and optimum conditions were investigated. Results indicated that the as-prepared magnesium silicate hollow spheres exhibited outstanding CTL properties such as stable intensity, high signal/noise values, and short response and recovery times. Under optimized conditions, benzene exhibited a broad linear range of 1-4500 ppm, with a correlation coefficient of 0.9946 and a limit of detection (signal-to-noise ratio (S/N) = 3) of 0.6 ppm, which was below the standard permitted concentration. The relative standard deviation (RSD) for 100 ppm benzene was 4.3% (n = 6). Furthermore, the gas sensor system showed outstanding selectivity for benzene compared with nine other common volatile organic compounds (VOCs). The proposed gas sensor showed good characteristics of high selectivity, fast response time and long lifetime, which suggested the promising application of magnesium silicate hollow spheres as a novel highly efficient CTL sensing material. The mechanism for the improved performance was also discussed based on the experimental results"
Keywords:Air/analysis Benzene/*analysis Calibration Equipment Design Limit of Detection Luminescent Measurements/instrumentation/*methods Magnesium Silicates/*chemistry Nanostructures/chemistry Sensitivity and Specificity Signal-To-Noise Ratio Temperature benzene;
Notes:"MedlineWang, Yuhuai Li, Bo Wang, Qihui Shou, Zhouxiang eng Research Support, Non-U.S. Gov't England 2014/10/29 Luminescence. 2015 Aug; 30(5):619-24. doi: 10.1002/bio.2795. Epub 2014 Oct 28"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024