Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractAn experimental set up of a PAH vapour generator and its use to test an annular denuder    Next AbstractDiscrimination of SARS-CoV-2 Infections From Other Viral Respiratory Infections by Scent Detection Dogs »

Environ Sci Technol


Title:A denuder-filter sampling technique for the detection of gas and particle phase carbonyl compounds
Author(s):Temime B; Healy RM; Wenger JC;
Address:"Department of Chemistry and Environmental Research Institute, University College Cork, Cork, Ireland"
Journal Title:Environ Sci Technol
Year:2007
Volume:41
Issue:18
Page Number:6514 - 6520
DOI: 10.1021/es070802v
ISSN/ISBN:0013-936X (Print) 0013-936X (Linking)
Abstract:"A denuder-filter sampling technique for the simultaneous collection of gas and particle phase carbonyl compounds has been developed and tested. The denuder was coated with XAD-4 resin and the derivatizing agent O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine (PFBHA) to enable on-tube conversion of gas-phase carbonyls to their oxime derivatives which were extracted and identified by GC-MS. The performance of the PFBHA-coated denuder was tested on a range of carbonyls, dicarbonyls, aromatic aldehydes, carbonyl-containing furans, and benzoquinones. The collection efficiency of the PFBHA-coated denuder was over 90% for sampling times of 10 min and significantly higher than when using only XAD-4 as the sorbent. The collection efficiency and rate of on-tube derivatization was highest for aldehydes and lowest for ketones, consistent with the expected reactivity of carbonyls with PFBHA. The method was used to separate the gas and particle phase carbonyl products formed during the photooxidation of toluene in order to assess its potential for application to simulation chamber experiments of VOC oxidation. The results indicate that when compared to a conventional filter sampling setup, the PFBHA-coated denuder-filter reduced the extent of gas phase adsorption onto the filter by at least a factor of 2 for each of the carbonyls formed. Further potential applications of the denuder-filter sampling method are discussed"
Keywords:Aerosols/analysis/*chemistry Environmental Monitoring/methods Filtration/methods Organic Chemicals/analysis/*chemistry Particle Size Volatilization;
Notes:"MedlineTemime, Brice Healy, Robert M Wenger, John C eng Research Support, Non-U.S. Gov't 2007/10/24 Environ Sci Technol. 2007 Sep 15; 41(18):6514-20. doi: 10.1021/es070802v"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 16-11-2024