Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractDegradation of methanethiol in anaerobic sewers and its correlation with methanogenic activities    Next AbstractCharacterization of Key Odorants in Hanyuan and Hancheng Fried Pepper (Zanthoxylum bungeanum) Oil »

Spectrochim Acta A Mol Biomol Spectrosc


Title:Detection of multiple chemicals based on external cavity quantum cascade laser spectroscopy
Author(s):Sun J; Ding J; Liu N; Yang G; Li J;
Address:"Key Laboratory of Opto-Electronic Information Acquisition and Manipulation of Ministry of Education, Anhui University, 230601 Hefei, China. Chongqing Engineering Laboratory for Detection, Control and Integrated System, Chongqing Technology and Business University, 400067 Chongqing, China. Key Laboratory of Opto-Electronic Information Acquisition and Manipulation of Ministry of Education, Anhui University, 230601 Hefei, China. Electronic address: jingsong_li@ahu.edu.cn"
Journal Title:Spectrochim Acta A Mol Biomol Spectrosc
Year:2018
Volume:20171105
Issue:
Page Number:532 - 538
DOI: 10.1016/j.saa.2017.10.059
ISSN/ISBN:1873-3557 (Electronic) 1386-1425 (Linking)
Abstract:"A laser spectroscopy system based on a broadband tunable external cavity quantum cascade laser (ECQCL) and a mini quartz crystal tuning fork (QCTF) detector was developed for standoff detection of volatile organic compounds (VOCs). The self-established spectral analysis model based on multiple algorithms for quantitative and qualitative analysis of VOC components (i.e. ethanol and acetone) was detailedly investigated in both closed cell and open path configurations. A good agreement was obtained between the experimentally observed spectra and the standard reference spectra. For open path detection of VOCs, the sensor system was demonstrated at a distance of 30m. The preliminary laboratory results show that standoff detection of VOCs at a distance of over 100m is very promising"
Keywords:Ecqcl Open path Qctf VOCs detection;
Notes:"PubMed-not-MEDLINESun, Juan Ding, Junya Liu, Ningwu Yang, Guangxiang Li, Jingsong eng England 2017/11/03 Spectrochim Acta A Mol Biomol Spectrosc. 2018 Feb 15; 191:532-538. doi: 10.1016/j.saa.2017.10.059. Epub 2017 Nov 5"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 25-11-2024