Title: | Non-targeted Gas Chromatography Orbitrap Mass Spectrometry qualitative and quantitative analysis of semi-volatile organic compounds in indoor dust using the Regions of Interest Multivariate Curve Resolution chemometrics procedure |
Author(s): | Pourasil RSM; Cristale J; Lacorte S; Tauler R; |
Address: | "Department of Environmental Chemistry, IDAEA-CSIC, Jordi Girona 18-26, Barcelona 08034. School of Technology, University of Campinas-UNICAMP, Paschoal Marmo 1888, Limeira, SP 13484-332, Brazil. Department of Environmental Chemistry, IDAEA-CSIC, Jordi Girona 18-26, Barcelona, 08034. Electronic address: Roma.tauler@idaea.csic.es" |
DOI: | 10.1016/j.chroma.2022.462907 |
ISSN/ISBN: | 1873-3778 (Electronic) 0021-9673 (Linking) |
Abstract: | "In this study, non-targeted gas chromatography-Orbitrap-mass spectrometry (GC-Orbitrap-MS) analysis of semi-volatile organic compounds (SVOCs) in indoor environmental dust samples is proposed. High-resolution mass spectrometry (HRMS) provides massive amounts of information-rich mass data which presents storage and processing challenges. Thus, a combination of the regions of interest (ROI) data filtering and mass compression method, together with the multivariate curve resolution-alternating least squares (MCR-ALS) data resolution method (which is called the ROIMCR procedure), is applied to solve huge data analysis challenges. The ROI method assures a significant reduction of the computer storage requirements of mass spectrometry data without any significant loss of spectral resolution nor of accuracy on m/z measures. On the other side, the MCR-ALS method allows the total resolution of the elution and spectral profiles of the different constituents present in the analyzed samples, not requiring their chromatographic peak alignment nor their chromatographic peak shape modelling using natural constraints like non-negativity. Since all the possible species are investigated by the ROIMCR method, it is a powerful tool for non-targeted analysis. In order to check that the sample constituents are correctly recovered and identified by the proposed ROIMCR procedure when is applied to non-targeted GC-Orbitrap-MS analysis, a set of lab-emulated dust samples at different concentration levels were qualitatively and quantitatively analyzed in detail. Then, to evaluate the performance of the proposed ROIMCR procedure, this method was applied to the same type of non-targeted GC-Orbitrap-MS analysis data of two real dust samples with unknown compositions. Many chemical compounds present in the lab-emulated dust samples were correctly identified and quantified in these dust samples. An additional number of extra chemical compounds were resolved in these real dust samples, whose identification as putative constituents of these samples is proposed. The ROIMCR procedure proposed in this work facilitates the simultaneous data processing of complex analytical samples and allows the detection and identification of possible extra sample constituents. As a final conclusion of this work, the combination of the GC-Orbitrap-MS and ROIMCR methods, is shown to be a reliable tool for the non-targeted qualitative and quantitative analysis of complex analytical and environmental samples" |
Keywords: | Chemometrics Dust Gas Chromatography-Mass Spectrometry/methods Mass Spectrometry *Volatile Organic Compounds GC-Orbitrap-MS Mcr-als Non-targeted analysis Roi Roimcr; |
Notes: | "MedlinePourasil, Roudabeh Sadat Moazeni Cristale, Joyce Lacorte, Silvia Tauler, Roma eng Netherlands 2022/03/12 J Chromatogr A. 2022 Apr 12; 1668:462907. doi: 10.1016/j.chroma.2022.462907. Epub 2022 Feb 16" |