Title: | Field performance test of an air-cleaner with photocatalysis-plasma synergistic reactors for practical and long-term use |
Author(s): | Ochiai T; Ichihashi E; Nishida N; Machida T; Uchida Y; Hayashi Y; Morito Y; Fujishima A; |
Address: | "Kanagawa Academy of Science and Technology, KSP East 407, 3-2-1 Sakado, Takatsu-ku, Kawasaki, Kanagawa 213-0012, Japan. pg-ochiai@newkast.or.jp. PACT World Co. Ltd., Domicile 301, 1-3-1 Sugeinadazutsumi, Tama-ku, Kawasaki, Kanagawa 214-0003, Japan. ichihashi@impact-world.jp. Tanashin Denki Co. Ltd., 8-19-20 Fukasawa, Setagaya-ku, Tokyo 158-0081, Japan. nishidan@tanashin.co.jp. Tanashin Denki Co. Ltd., 8-19-20 Fukasawa, Setagaya-ku, Tokyo 158-0081, Japan. machida@tanashin.co.jp. Tanashin Denki Co. Ltd., 8-19-20 Fukasawa, Setagaya-ku, Tokyo 158-0081, Japan. uchiday@tanashin.co.jp. PACT World Co. Ltd., Domicile 301, 1-3-1 Sugeinadazutsumi, Tama-ku, Kawasaki, Kanagawa 214-0003, Japan. hayashi@impact-world.jp. Photocatalysis International Research Center, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba 278-8510, Japan. y.morito@u-vix.com. Kanagawa Academy of Science and Technology, KSP East 407, 3-2-1 Sakado, Takatsu-ku, Kawasaki, Kanagawa 213-0012, Japan. y.morito@u-vix.com" |
DOI: | 10.3390/molecules191117424 |
ISSN/ISBN: | 1420-3049 (Electronic) 1420-3049 (Linking) |
Abstract: | "A practical and long-term usable air-cleaner based on the synergy of photocatalysis and plasma treatments has been developed. A field test of the air-cleaner was carried out in an office smoking room. The results were compared to previously reported laboratory test results. Even after a treatment of 12,000 cigarettes-worth of tobacco smoke, the air-cleaner maintained high-level air-purification activity (98.9% +/- 0.1% and 88% +/- 1% removal of the total suspended particulate (TSP) and total volatile organic compound (TVOC) concentrations, respectively) at single-pass conditions. Although the removal ratio of TSP concentrations was 98.6% +/- 0.2%, the ratio of TVOC concentrations was 43.8% after a treatment of 21,900 cigarettes-worth of tobacco smoke in the field test. These results indicate the importance of suitable maintenance of the reactors in the air-cleaner during field use" |
Keywords: | Catalysis Equipment Design/*instrumentation/*methods Respiratory Protective Devices Smoking/*adverse effects Tobacco Smoke Pollution/*adverse effects; |
Notes: | "MedlineOchiai, Tsuyoshi Ichihashi, Erina Nishida, Naoki Machida, Tadashi Uchida, Yoshitsugu Hayashi, Yuji Morito, Yuko Fujishima, Akira eng Switzerland 2014/10/31 Molecules. 2014 Oct 29; 19(11):17424-34. doi: 10.3390/molecules191117424" |