Title:Evidence of a sewer vapor transport pathway at the USEPA vapor intrusion research duplex
Author(s):McHugh T; Beckley L; Sullivan T; Lutes C; Truesdale R; Uppencamp R; Cosky B; Zimmerman J; Schumacher B;
Address:"GSI Environmental Inc., Houston, TX, United States. Electronic address: temchugh@gsi-net.com. GSI Environmental Inc., Austin, TX, United States. Brookhaven National Laboratory, Upton, NY, United States. CH2MHill, Inc., Raleigh, NC, United States. RTI International, Research Triangle Park, NC, United States. Arcadis, Indianapolis, IN, United States. US Environmental Protection Agency, Las Vegas, NV, United States"
Journal Title:Sci Total Environ
Year:2017
Volume:20170426
Issue:
Page Number:772 - 779
DOI: 10.1016/j.scitotenv.2017.04.135
ISSN/ISBN:1879-1026 (Electronic) 0048-9697 (Print) 0048-9697 (Linking)
Abstract:"The role of sewer lines as preferential pathways for vapor intrusion is poorly understood. Although the importance of sewer lines for volatile organic compound (VOC) transport has been documented at a small number of sites with vapor intrusion, sewer lines are not routinely sampled during most vapor intrusion investigations. We have used a tracer study and VOC concentration measurements to evaluate the role of the combined sanitary/storm sewer line in VOC transport at the USEPA vapor intrusion research duplex in Indianapolis, Indiana. The results from the tracer study demonstrated gas migration from the sewer main line into the duplex. The migration pathway appears to be complex and may include leakage from the sewer lateral at a location below the building foundation. Vapor samples collected from the sewer line demonstrated the presence of tetrachloroethene (PCE) and chloroform in the sewer main in front of the duplex and at multiple sample locations within the sewer line upstream of the duplex. These test results combined with results from the prior multi-year study of the duplex indicate that the sewer line plays an important role in transport of VOCs from the subsurface source to the immediate vicinity of the duplex building envelope"
Keywords:Indianapolis Preferential pathway Utility tunnel;
Notes:"PubMed-not-MEDLINEMcHugh, Thomas Beckley, Lila Sullivan, Terry Lutes, Chris Truesdale, Robert Uppencamp, Rob Cosky, Brian Zimmerman, John Schumacher, Brian eng EPA999999/Intramural EPA/ Netherlands 2017/04/30 Sci Total Environ. 2017 Nov 15; 598:772-779. doi: 10.1016/j.scitotenv.2017.04.135. Epub 2017 Apr 26"

 