Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractDevelopment of the detection threshold concept from a close look at sorption occurrence inside a glass vial based on the in-vial vaporization of semivolatile fatty acids    Next AbstractCritical role of a pre-purge setup in the thermal desorption analysis of volatile organic compounds by gas chromatography with mass spectrometry »

Anal Chim Acta


Title:Experimental validation of an effective carbon number-based approach for the gas chromatography-mass spectrometry quantification of 'compounds lacking authentic standards or surrogates'
Author(s):Kim YH; Kim KH; Szulejko JE; Bae MS; Brown RJ;
Address:"Department of Civil & Environmental Engineering, Hanyang University, 222 Wangsimni-Ro, Seoul 133-791, Republic of Korea. Department of Civil & Environmental Engineering, Hanyang University, 222 Wangsimni-Ro, Seoul 133-791, Republic of Korea. Electronic address: kkim61@hanyang.ac.kr. Department of Environmental Engineering, Mokpo National University, Mokpo, Republic of Korea. Analytical Science Division, National Physical Laboratory, Hampton Road, Teddington TW11 0LW, UK"
Journal Title:Anal Chim Acta
Year:2014
Volume:20140430
Issue:
Page Number:32 - 41
DOI: 10.1016/j.aca.2014.04.052
ISSN/ISBN:1873-4324 (Electronic) 0003-2670 (Linking)
Abstract:"For the quantitative analysis of 'compounds lacking authentic standards or surrogates' (CLASS) in environmental media, we previously introduced an effective carbon number (ECN) approach to develop an empirical equation for the prediction of their response factor (RF). In this research, a series of laboratory experiments were carried out to benchmark the reliability of an ECN approach for sorbent tube/thermal desorption/gas chromatography (GC)/mass spectrometry (MS) applications. First, the ECN values were determined using external calibration data from 25 reference volatile organic compounds (VOCs) using two MS dectectors (quadrupole (Q) and time-of-flight (TOF)). Then, a certified standard mixture of 54 VOCs was analyzed by each system as a simulated unknown sample. The analytical bias, assessed in terms of percentage difference (PD) between the certified and ECN-predicted mass values, averaged 19.2+/-16.1% (TOF-MS) and 28.2+/-27.6% (Q-MS). The bias using a more simplified carbon number (CN)-based prediction increased considerably, yielding 53.4+/-53.3% (TOF-MS) and 61.7+/-81.3% (Q-MS). However, the bias obtained using the ECN-based prediction decreased significantly to yield average PD values of 9.84+/-7.28% (TOF-MS) and 16.8+/-8.35% (Q-MS), if the comparison was limited to 26 (out of 54) VOCs with CN>/=4 (i.e., 25 aromatics and hexachlorobutadiene)"
Keywords:Carbon number Effective carbon number Gas chromatography/mass spectrometry applications Sorbent tube Thermal desorption Volatile organic compound;
Notes:"PubMed-not-MEDLINEKim, Yong-Hyun Kim, Ki-Hyun Szulejko, Jan E Bae, Min-Suk Brown, Richard J C eng Netherlands 2014/05/27 Anal Chim Acta. 2014 Jun 9; 830:32-41. doi: 10.1016/j.aca.2014.04.052. Epub 2014 Apr 30"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 25-12-2024