Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractMale cephalic labial gland secretions of two bumblebee species of the subgenus Cullumanobombus (Hymenoptera: Apidae: Bombus latreille) and their distribution in central Europe    Next AbstractDiffusion-controlled toluene reference material for VOC emissions testing: international interlaboratory study »

J Air Waste Manag Assoc


Title:Development of a field test method to evaluate gaseous air cleaner performance in a multizone building
Author(s):Howard-Reed C; Henzel V; Nabinger SJ; Persily AK;
Address:"Building and Fire Research Laboratory, National Institute of Standards and Technology, Gaithersburg, MD 20899-8633, USA. chreed@nist.gov"
Journal Title:J Air Waste Manag Assoc
Year:2008
Volume:58
Issue:7
Page Number:919 - 927
DOI: 10.3155/1047-3289.58.7.919
ISSN/ISBN:1096-2247 (Print) 1096-2247 (Linking)
Abstract:"The performance of gaseous air cleaners for commercial and residential buildings has typically been evaluated using test protocols developed for a controlled laboratory chamber or a test duct. It is currently unknown how laboratory measurements relate to the actual performance of an air cleaner installed in a real building. However, to date, there are no air cleaner field test protocols available, thereby limiting the existing field data. The National Institute of Standards and Technology (NIST) has conducted a series of experiments to support test procedure development for evaluating the installed performance of gaseous air cleaning equipment, as well as metrics for characterizing field performance. To date, over 100 experiments have been completed, of which 23 portable air cleaner experiments and 6 in-duct air cleaner experiments are described in this paper. Tests were conducted in a finished three-bedroom/two-bathroom manufactured house equipped with several gas chromatographs to semi-continuously measure air change rates and volatile organic compound concentrations. Experimental variables included air cleaner location, isolation of zones by closing doors, and contaminant source location. For each experiment, air cleaner removal of decane was directly measured using the air cleaner inlet and outlet concentrations, as well as with mass balance analyses using measured room concentrations. With a verified mass balance model, a field performance metric was developed to compare installed whole-building performance to the performance predicted by a laboratory result. The results provide insight into the protocols and metrics that might prove useful for characterizing the field performance of air cleaners as well as the impact of air cleaner removal on zonal concentration levels in a variety of situations"
Keywords:"*Air Pollution, Indoor *Environmental Monitoring Filtration Time Factors Ventilation;"
Notes:"MedlineHoward-Reed, Cynthia Henzel, Victor Nabinger, Steven J Persily, Andrew K eng 2008/08/05 J Air Waste Manag Assoc. 2008 Jul; 58(7):919-27. doi: 10.3155/1047-3289.58.7.919"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 16-11-2024