Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractComment on 'Bioinspired Reversible Switch between Underwater Superoleophobicity/Superaerophobicity and Oleophilicity/Aerophilicity and Improved Antireflective Property on the Nanosecond Laser-Ablated Superhydrophobic Titanium Surfaces'    Next Abstract"Experimental habitat scenting inhibits colonization by beaver,Castor canadensis" »

J Occup Environ Med


Title:Indoor Air Quality and Environmental Sampling as Support Tools to Detect SARS-CoV-2 in the Healthcare Setting
Author(s):Gregorio PHP; Mariani AW; Brito J; Santos BJM; Pego-Fernandes PM;
Address:"Thoracic Surgery Department, Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo - Sao Paulo, Sao Paulo, Brazil (Drs Gregorio, Mariani, Brito, Santos, and Fernandes)"
Journal Title:J Occup Environ Med
Year:2021
Volume:63
Issue:11
Page Number:956 - 962
DOI: 10.1097/JOM.0000000000002284
ISSN/ISBN:1536-5948 (Electronic) 1076-2752 (Print) 1076-2752 (Linking)
Abstract:"OBJECTIVES: To evaluate severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spread inside the healthcare setting using environmental sampling and indoor air quality (IAQ) parameters. METHODS: Ward/ICU rooms had IAQ parameters monitored in real-time, including volatile organic compounds and particulate matter. Surface and three air samples with different exposure times were collected in each room and tested for SARS-CoV-2 using quantitative Rt-PCR. Environmental sampling and IAQ data were compared to provide information about viral spread. RESULTS: SARS-CoV-2 RNA was detected in 6/10 rooms and 9/30 air samples, which is proportionally higher than previous studies. Sampling time confirmed to be crucial to viral detection. No correlations between IAQ parameters could be associated with positive/negative samples even when aerosol-generating procedures were performed. CONCLUSION: Environmental sampling of SARS-CoV-2 RNA may be used as an indicator of occupational safety. IAQ is also a potential tool but requires further research"
Keywords:"*Air Pollution, Indoor *covid-19 Delivery of Health Care Humans RNA, Viral SARS-CoV-2;"
Notes:"MedlineGregorio, Paulo Henrique Peitl Mariani, Alessandro Wasum Brito, Joao Marcelo Lopes Toscano Santos, Bruno Jose Martini Pego-Fernandes, Paulo Manuel eng 2021/11/06 J Occup Environ Med. 2021 Nov 1; 63(11):956-962. doi: 10.1097/JOM.0000000000002284"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 22-11-2024