Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractGas chromatography with diode array detection in series with flame ionisation detection    Next AbstractMiniaturized micromachined gas chromatography with universal and selective detectors for targeted volatile compounds analysis »

J Chromatogr A


Title:"Gas chromatography with simultaneous detection: Ultraviolet spectroscopy, flame ionization, and mass spectrometry"
Author(s):Gras R; Luong J; Haddad PR; Shellie RA;
Address:"Dow Chemical Canada ULC, Highway 15, Fort Saskatchewan, Alberta, T8L 2P4, Canada; ARC Training Centre for Portable Analytical Separation Technologies (ASTech), University of Tasmania, Private Bag 75, Hobart 7001, Australia; Australian Centre for Research on Separation Science (ACROSS), University of Tasmania, Private Bag 75, Hobart 7001, Australia. Dow Chemical Canada ULC, Highway 15, Fort Saskatchewan, Alberta, T8L 2P4, Canada; Australian Centre for Research on Separation Science (ACROSS), University of Tasmania, Private Bag 75, Hobart 7001, Australia. ARC Training Centre for Portable Analytical Separation Technologies (ASTech), University of Tasmania, Private Bag 75, Hobart 7001, Australia; Australian Centre for Research on Separation Science (ACROSS), University of Tasmania, Private Bag 75, Hobart 7001, Australia. ARC Training Centre for Portable Analytical Separation Technologies (ASTech), University of Tasmania, Private Bag 75, Hobart 7001, Australia; Trajan Scientific and Medical, 7 Argent Place, Ringwood 3134, Australia; School of Science, RMIT University, Private Bag 2476V, Melbourne 3001, Australia. Electronic address: RShellie@trajanscimed.com"
Journal Title:J Chromatogr A
Year:2018
Volume:20180508
Issue:
Page Number:171 - 179
DOI: 10.1016/j.chroma.2018.05.015
ISSN/ISBN:1873-3778 (Electronic) 0021-9673 (Linking)
Abstract:"An effective analytical strategy was developed and implemented to exploit the synergy derived from three different detector classes for gas chromatography, namely ultraviolet spectroscopy, flame ionization, and mass spectrometry for volatile compound analysis. This strategy was achieved by successfully hyphenating a user-selectable multi-wavelength diode array detector featuring a positive temperature coefficient thermistor as an isothermal heater to a gas chromatograph. By exploiting the non-destructive nature of the diode array detector, the effluent from the detector was split to two parallel detectors; namely a quadrupole mass spectrometer and a flame ionization detector. This multi-hyphenated configuration with the use of three detectors is a powerful approach not only for selective detection enhancement but also for improvement in structural elucidation of volatile compounds where fewer fragments can be obtained or for isomeric compound analysis. With the diode array detector capable of generating high resolution gas phase spectra, the information collected provides useful confirmatory information without a total dependence on the chromatographic separation process which is based on retention time. This information-rich approach to chromatography is achieved without incurring extra analytical time, resulting in improvements in compound identification accuracy, analytical productivity, and cost. Chromatographic performance obtained from model compounds was found to be acceptable with a relative standard deviation of the retention times of less than 0.01% RSD, and a repeatability at two levels of concentration of 100 and 1000ppm (v/v) of less than 5% (n=10). With this configuration, correlation of data between the three detectors was simplified by having near identical retention times for the analytes studied"
Keywords:"Alkenes/analysis Benzene/analysis Flame Ionization Gas Chromatography-Mass Spectrometry/*methods Nitrogen/analysis Spectrophotometry, Ultraviolet Volatile Organic Compounds/analysis Diode array detection Gas chromatography Heated DAD cell Hyphenation Mass;"
Notes:"MedlineGras, Ronda Luong, Jim Haddad, Paul R Shellie, Robert A eng Netherlands 2018/06/13 J Chromatogr A. 2018 Aug 17; 1563:171-179. doi: 10.1016/j.chroma.2018.05.015. Epub 2018 May 8"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 28-12-2024