Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractIdentification of responsible volatile chemicals that induce hypersensitive reactions to multiple chemical sensitivity patients    Next AbstractIndoor air quality and thermal comfort in temporary houses occupied after the Great East Japan Earthquake »

Indoor Air


Title:"Indoor air quality, air exchange rates, and radioactivity in new built temporary houses following the Great East Japan Earthquake in Minamisoma, Fukushima"
Author(s):Shinohara N; Tokumura M; Kazama M; Yoshino H; Ochiai S; Mizukoshi A;
Address:"Research Institute of Science for Safety and Sustainability, National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki, Japan. n-shinohara@aist.go.jp"
Journal Title:Indoor Air
Year:2013
Volume:20130321
Issue:4
Page Number:332 - 341
DOI: 10.1111/ina.12029
ISSN/ISBN:1600-0668 (Electronic) 0905-6947 (Linking)
Abstract:"This study measured air exchange rates, indoor concentrations of aldehydes and volatile organic compounds (VOCs), and radioactivity levels at 19 temporary houses in different temporary housing estate constructed in Minamisoma City following the Great East Japan Earthquake. The 19 surveyed houses represented all of the companies assigned to construct temporary houses in that Minamisoma City. Data were collected shortly after construction and before occupation, from August 2011 to January 2012. Mean air exchange rates in the temporary houses were 0.28/h, with no variation according to housing types and construction date. Mean indoor concentrations of formaldehyde, acetaldehyde, toluene, ethylbenzene, m/p-xylene, o-xylene, styrene, p-dichlorobenzene, tetradecane, and total VOCs (TVOCs) were 29.2, 72.7, 14.6, 6.35, 3.05, 1.81, 7.29, 14.3, 8.32, and 901 mug/m(3), respectively. The levels of acetaldehyde and TVOCs exceeded the indoor guideline (48 mug/m(3)) and interim target (400 mug/m(3)) in more than half of the 31 rooms tested. In addition to guideline chemicals, terpenes (alpha-pinene and d-limonene) and acetic esters (butyl acetate and ethyl acetate) were often detected in these houses. The indoor radiation levels measured by a Geiger-Muller tube (Mean: 0.22 muSv/h) were lower than those recorded outdoors (Mean: 0.42 muSv/h), although the shielding effect of the houses was less than for other types of buildings"
Keywords:"Air Pollutants, Radioactive/*analysis Air Pollution, Indoor/*analysis Aldehydes/*analysis Disasters Earthquakes Housing/*statistics & numerical data Japan Radioactivity Volatile Organic Compounds/*analysis Air exchange rates Aldehyde compounds Radioactivi;"
Notes:"MedlineShinohara, N Tokumura, M Kazama, M Yoshino, H Ochiai, S Mizukoshi, A eng England 2013/01/23 Indoor Air. 2013 Aug; 23(4):332-41. doi: 10.1111/ina.12029. Epub 2013 Mar 21"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 05-12-2024