Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractVariation in plant leaf traits affects transmission and detectability of herbivore vibrational cues    Next Abstract"Volatile Composition, Colour, and Sensory Quality of ?ª+Spirit-Based Beverages Enriched with Medicinal Fungus Ganoderma lucidum and Herbal Extract" »

Rapid Commun Mass Spectrom


Title:Open tube combustion method of organic samples for stable carbon isotope analysis
Author(s):Velivetskaya TA; Ignatyev AV; Reize MV; Kiyashko SI;
Address:"Far East Geological Institute FEB RAS, Vladivostok 690022, Russia. velivetskaya@mail.ru"
Journal Title:Rapid Commun Mass Spectrom
Year:2007
Volume:21
Issue:15
Page Number:2451 - 2455
DOI: 10.1002/rcm.3112
ISSN/ISBN:0951-4198 (Print) 0951-4198 (Linking)
Abstract:"A simple and effective method for the conversion of organic carbon into carbon dioxide for analysis of stable carbon isotopes (delta(13)C) in samples of various organic substances, soils, sedimentary rocks, oils and volatile organic liquids is presented. The conversion of organic carbon of the samples is carried out in a quartz reactor connected to a vacuum line for CO(2) freezing and purification. A solid organic sample mixed with CuO is placed at the reactor bottom and the reactor is subsequently filled with granular CuO. One end of the CuO column is preheated to 850 degrees C while the other end of the column in contact with the sample is kept at ambient temperature. Heating of the sample (850 degrees C) and the remainder of the column is then performed. The preheated part of the column provides efficient conversion of carbon into CO(2). The reactor for the conversion of volatile liquid organic compounds is filled with granular CuO. The column of CuO is heated to 850 degrees C. Samples of volatile liquids are introduced into the reactor through a septum using a microsyringe. Complete conversion takes 10 min for solid samples and 3 min for volatile liquids. The precision of the delta(13)C analysis for solid and volatile liquid organic substances is +/-0.1 per thousand and +/-0.04 per thousand, respectively"
Keywords:Carbon Dioxide/analysis/*chemistry Carbon Isotopes/analysis *Hot Temperature Mass Spectrometry/methods Organic Chemicals/*chemistry Reproducibility of Results;
Notes:"MedlineVelivetskaya, Tatiana A Ignatyev, Alexander V Reize, Marina V Kiyashko, Serguei I eng Validation Study England 2007/07/05 Rapid Commun Mass Spectrom. 2007; 21(15):2451-5. doi: 10.1002/rcm.3112"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024