Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractSynthetic pheromone biosynthesis activating neuropeptide gene expressed in a baculovirus expression system    Next AbstractOptimization of electronic nose drift correction applied to tomato volatile profiling »

J Chromatogr A


Title:Online detection and measurement of elemental mercury vapor by ion mobility spectrometry with chloroform dopant
Author(s):Valadbeigi Y; Ilbeigi V; Vahidi M; Michalczuk B; Matejcik S; Tabrizchi M;
Address:"Department of Chemistry, Faculty of Science, Imam Khomeini International University, Qazvin, Iran. Electronic address: valadbeigi@sci.ikiu.ac.ir. TOF Tech. Pars Company, Isfahan Science & Technology Town, Isfahan, Iran. Gas Research Division, Research Institute of Petroleum Industry (RIPI), 1485613111, Tehran, Iran. Department of Experimental Physics, Comenius University, Mlynska dolina F2, 84248 Bratislava, Slovak Republic. Department of Chemistry, Isfahan University of Technology, Isfahan, 84156-83111, Iran. Electronic address: m-tabriz@cc.iut.ac.ir"
Journal Title:J Chromatogr A
Year:2020
Volume:20201112
Issue:
Page Number:461676 -
DOI: 10.1016/j.chroma.2020.461676
ISSN/ISBN:1873-3778 (Electronic) 0021-9673 (Linking)
Abstract:"A rapid and simple method is proposed for detection of elemental mercury (Hg) vapor by ion mobility spectrometry (IMS). Negative corona discharge (CD) as the ionization source and chloroform as the dopant gas were used to produce Cl(-) reactant ion. A mass spectrum of the product ions confirmed that the mechanism of ionization is based on Cl(-) anion attachment to Hg and formation of HgCl(-) ion. It was found that the optimum drift gas temperature for Hg detection was about 160 degrees C and the drift gas flow rate should be minimized and just sufficient to clear contaminants and carry-over from the drift cell. The drift time of the HgCl(-) peak relative to that of the Cl(-) peak at 160 degrees C is 1.52 ms corresponding to the reduced mobility of 1.90 cm(2)/Vs. Because many volatile organic compounds (VOCs) such as alcohols, amines, aldehydes, ketones, and alkanes are not ionized in the negative mode of CD-IMS, these compounds do not interfere with the detection of Hg. Mercaptans peaks also did not show any interference with the Hg signal. Hence, the method is highly selective for detection of Hg in natural gas containing sulfur compounds. The detection limit of Hg obtained by the proposed method was 0.07 mg/m(3). The method was successfully verified in determination of the mercury vapor content of a fluorescent lamp, as a real sample"
Keywords:"Alcohols Chemistry Techniques, Analytical/instrumentation/*methods Chloroform/*chemistry Gases/*analysis/chemistry *Ion Mobility Spectrometry Ions/chemistry Mercury/*analysis Natural Gas/analysis Sulfur Compounds/chemistry Temperature Volatile Organic Com;"
Notes:"MedlineValadbeigi, Younes Ilbeigi, Vahideh Vahidi, Mehdi Michalczuk, Bartosz Matejcik, Stefan Tabrizchi, Mahmoud eng Netherlands 2020/11/23 J Chromatogr A. 2020 Dec 20; 1634:461676. doi: 10.1016/j.chroma.2020.461676. Epub 2020 Nov 12"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024