Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractOn-line multibed sorption trap and injector for the GC analysis of organic vapors in large-volume air samples    Next AbstractPerformance characteristics of a new prototype for a portable GC using ambient air as carrier gas for on-site analysis »

J Sep Sci


Title:"On-line multi-bed sorption trap for VOC analysis of large-volume vapor samples: injection plug width, effects of water vapor and sample decomposition"
Author(s):Sanchez JM; Sacks RD;
Address:"Department of Chemistry, University of Michigan, Ann Arbor, MI 48109, USA. juanma.sanchez@udg.es"
Journal Title:J Sep Sci
Year:2005
Volume:28
Issue:1
Page Number:22 - 30
DOI: 10.1002/jssc.200401881
ISSN/ISBN:1615-9306 (Print) 1615-9306 (Linking)
Abstract:"A multibed on-line sorption trap is used to preconcentrate organic vapors from air samples and inject the analytes into a GC separation column. Injection plug widths depend on the boiling point for the lipophilic compounds and on the polarity and boiling point for the polar compounds. Injection plug widths are sufficiently small (0.7-0.8 s) as to allow the direct injection of the most volatile compounds into the GC column without the need for a second focusing device. The presence of water in the samples has an effect on the retention of polar compounds by the trap. However, this effect is reproducible for a fixed water content and so can be overcome by using calibration standards under the same conditions of humidity as the samples. The thermal decomposition of many volatile organic compounds in an on-line sorption trap during the GC analysis of air samples is examined. The results show that degradation of unstable compounds is governed by the amount of heat transferred to the compounds during desorption (i.e., applied temperature and pulse duration). The use of an on-line trap results in the immediate transfer of desorbed compounds to the analytical column, which can reduce the formation of artifacts"
Keywords:
Notes:"PubMed-not-MEDLINESanchez, Juan M Sacks, Richard D eng Germany 2005/02/04 J Sep Sci. 2005 Jan; 28(1):22-30. doi: 10.1002/jssc.200401881"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024