Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"The perirhinal-entorhinal cortex, but not the hippocampus, is critical for expression of individual recognition in the context of the Coolidge effect"    Next AbstractVolatiles from potential hosts of Rhopalicus tutela a bark beetle parasitoid »

Environ Sci Process Impacts


Title:A standard method for measuring benzene and formaldehyde emissions from candles in emission test chambers for human health risk assessment purposes
Author(s):Petry T; Cazelle E; Lloyd P; Mascarenhas R; Stijntjes G;
Address:"ToxMinds BVBA, Product Safety & Regulatory Affairs, 1200 Brussels, Belgium. thomas.petry@toxminds.com"
Journal Title:Environ Sci Process Impacts
Year:2013
Volume:15
Issue:7
Page Number:1369 - 1382
DOI: 10.1039/c3em00011g
ISSN/ISBN:2050-7895 (Electronic) 2050-7887 (Linking)
Abstract:"Burning candles release a number of volatile or semi-volatile organic compounds (VOC; SVOC) and particulate matters into indoor air. Publicly available candle emission studies vary in protocols and factors known to have a great influence on combustion processes, making it difficult to determine potential implications of candle emissions for human health. The main objective of this investigation was to establish and standardize as far as possible a candle VOC emission testing protocol in small- to mid-scale test chambers on the basis of existing standards as well as to verify its suitability for human health risk assessment purposes. Two pilot studies were conducted to define the boundaries of permissible variations in chamber parameters without significantly impacting the quality of the candle burn. A four-centre ring trial assessed the standardised protocol. The ring trial revealed that when the laboratories were able to control the chamber parameters within the defined boundaries, reproducible formaldehyde and benzene emissions, considered as VOC markers, are determined. It was therefore concluded that the protocol developed in this investigation is suitable for generating candle VOC emission data for human health risk assessment purposes"
Keywords:"Air Pollution, Indoor/*analysis Benzene/*analysis Carcinogens/*analysis Consumer Product Safety Environmental Monitoring Formaldehyde/*analysis Humans Inhalation Exposure/*analysis Risk Assessment Volatile Organic Compounds/*analysis;"
Notes:"MedlinePetry, Thomas Cazelle, Elodie Lloyd, Paul Mascarenhas, Reuben Stijntjes, Gerard eng Research Support, Non-U.S. Gov't England 2013/05/23 Environ Sci Process Impacts. 2013 Jul; 15(7):1369-82. doi: 10.1039/c3em00011g"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024