Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractImpact of cigarette smoking on volatile organic compound (VOC) blood levels in the U.S. population: NHANES 2003-2004    Next AbstractMale mating competitiveness of a Wolbachia-introgressed Aedes polynesiensis strain under semi-field conditions »

ACS Omega


Title:Method for Accurate Quantitation of Volatile Organic Compounds in Urine Using Point of Collection Internal Standard Addition
Author(s):Chambers DM; Edwards KC; Sanchez E; Reese CM; Fernandez AT; Blount BC; De Jesus VR;
Address:"Tobacco and Volatiles Branch, Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, 4770 Buford Highway MS S103-3, Atlanta, Georgia 30341, United States"
Journal Title:ACS Omega
Year:2021
Volume:20210504
Issue:19
Page Number:12684 - 12690
DOI: 10.1021/acsomega.1c00854
ISSN/ISBN:2470-1343 (Electronic) 2470-1343 (Linking)
Abstract:"A method to achieve accurate measurement of unmetabolized volatile organic compounds (VOCs) in urine was developed and characterized. The method incorporates a novel preanalytical approach of adding isotopically labeled internal standard (ISTD) analogues directly to the collection container at the point of collection to compensate for analyte loss to the headspace and the collection container surfaces. Using this approach, 45 toxic VOCs ranging in water solubility and boiling point were evaluated and analyzed by headspace solid-phase microextraction/gas chromatography-mass spectrometry. Results show that urine VOCs could be equally lost to the container headspace as to the container surface suggesting similarity of these two regions as partition phases. Surface adsorption loss was found to trend with compound water solubility. In particular, with no headspace, more nonpolar VOCs experienced substantial losses (e.g., 48% for hexane) in a standard 120 mL urine cup at concentrations in the low- and sub-ppb range. The most polar VOCs evaluated (e.g., tetrahydrofuran) showed no significant loss. Other commonly practiced methods for urine sample collection and analysis such as aliquoting, specimen freezing, and use of surrogate ISTD were found to significantly bias results. With this method, we achieved errors ranging from -8.0 to 4.8% of spiked urine specimens. Paired urine and blood specimens from cigarette smokers were compared to assess this method"
Keywords:
Notes:"PubMed-not-MEDLINEChambers, David M Edwards, Kasey C Sanchez, Eduardo Reese, Christopher M Fernandez, Alai T Blount, Benjamin C De Jesus, Victor R eng 2021/06/01 ACS Omega. 2021 May 4; 6(19):12684-12690. doi: 10.1021/acsomega.1c00854. eCollection 2021 May 18"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024