Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractA systemic view on the distribution of diet-derived methanol and hepatic acetone in mice    Next AbstractScreening of drugs that suppress Ste11 MAPKKK activation in yeast identified a c-Abl tyrosine kinase inhibitor »

Yakugaku Zasshi


Title:[Studies on residue on ignition test in JP]
Author(s):Kitagawa T; Umeyama Y; Hirata K; Koda S;
Address:"Fujisawa Pharmaceutical Co., Ltd., Analytical Research Laboratories, 2-1-6, Kashima, Yodogawa-ku, Osaka 532-8514, Japan. teruyuki_kitagawa@po.fujisawa.co.jp"
Journal Title:Yakugaku Zasshi
Year:2002
Volume:122
Issue:1
Page Number:121 - 125
DOI: 10.1248/yakushi.122.121
ISSN/ISBN:0031-6903 (Print) 0031-6903 (Linking)
Abstract:"The Residue on Ignition Test specified in General Tests, Japanese Pharmacopeia is a method to measure the weight of the residual substance not volatilized when the sample is ignited under a constant condition. Generally, this test is intended to determine the content of inorganic substances contained as impurities in an organic substance, and, occasionally, to determine the amount of inorganic substances contained as components in an organic substance. Our laboratories have adopted this test method for the above two purposes in the case of the quality control for drug substances, synthetic intermediates, starting materials in the course of drug development. Some validation studies have been conducted for this test in order to clarify the quantitation limit in the case of an application for the former purpose, and trueness and precision in the case of the latter purpose. Consequently, the quantitation limit was determined as around 0.50 mg. The amount of sample should be determined based on this quantitation limit (mg) and the level of quantitation limit (%) or that of specification limit (%) should be considered from the view point of each testing purpose. The test method was also confirmed to have a good trueness and precision as the determination method for an alkaline salt, such as sodium, potassium or calcium salt, of organic compounds, as long as the test is operated with great care not to scatter the content out of crucible during ignition to incineration"
Keywords:"Calcium/analysis Chemistry Techniques, Analytical/*methods Chemistry, Pharmaceutical/*methods *Drug Contamination *Incineration Inorganic Chemicals/analysis Japan Pharmaceutical Preparations/*chemistry *Pharmacopoeias as Topic Potassium/analysis Quality C;"
Notes:"MedlineKitagawa, Teruyuki Umeyama, Yumi Hirata, Kaoru Koda, Shigetaka jpn English Abstract Japan 2002/02/07 Yakugaku Zasshi. 2002 Jan; 122(1):121-5. doi: 10.1248/yakushi.122.121"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024