Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractSample preparation for the analysis of volatile organic compounds in air and water matrices    Next AbstractVapour permeation measurements with free-standing nanomembranes »

J Chromatogr A


Title:Quality control in quantification of volatile organic compounds analysed by thermal desorption-gas chromatography-mass spectrometry
Author(s):Demeestere K; Dewulf J; De Roo K; De Wispelaere P; Van Langenhove H;
Address:"Research Group EnVOC, Department of Organic Chemistry, Faculty of Bioscience Engineering, Ghent University, Coupure Links 653, B-9000 Ghent, Belgium"
Journal Title:J Chromatogr A
Year:2008
Volume:20071119
Issue:1-Feb
Page Number:348 - 357
DOI: 10.1016/j.chroma.2007.11.036
ISSN/ISBN:0021-9673 (Print) 0021-9673 (Linking)
Abstract:"This paper presents a detailed study on the calibration of a thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS)-based methodology for quantification of volatile organic compounds (VOCs) in gaseous and liquid samples. For the first time, it is documented to what extent three widely encountered problems affect precise and accurate quantification, and solutions to improve calibration are proposed. The first issue deals with the limited precision in MS quantification, as exemplified by high relative standard deviations (up to 40%, n=5) on response factors of a set of 69 selected VOCs in a volatility range from 16 Pa to 85 kPa at 298 K. The addition of [(2)H(8)]toluene as an internal standard, in gaseous or liquid phase, improves this imprecision by a factor of 5. Second, the matrix in which the standard is dissolved is shown to be highly important towards calibration. Quantification of gaseous VOCs loaded on a sorbent tube using response factors obtained with liquid standards results in systematic deviations of 40-80%. Relative response factors determined by the analysis of sorbent tubes loaded with both analytes and [(2)H(8)]toluene from liquid phase are shown to offer a reliable alternative for quantification of airborne VOCs, without need for expensive and often hardly available gaseous standards. Third, a strategy is proposed involving the determination of a relative response factor being representative for a group of analytes with similar functionalities and electron impact fragmentation patterns. This group method approach indicates to be useful (RSD approximately 10%) for quantifying analytes belonging to that class but having no standards available"
Keywords:Gas Chromatography-Mass Spectrometry/*methods/*standards Organic Chemicals/*analysis/chemistry Quality Control Reference Standards *Temperature Time Factors Volatilization;
Notes:"MedlineDemeestere, Kristof Dewulf, Jo De Roo, Karlien De Wispelaere, Patrick Van Langenhove, Herman eng Netherlands 2007/12/08 J Chromatogr A. 2008 Apr 4; 1186(1-2):348-57. doi: 10.1016/j.chroma.2007.11.036. Epub 2007 Nov 19"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024