Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Effect of high-pressure homogenization, nonfat milk solids, and milkfat on the technological performance of a functional strain for the production of probiotic fermented milks"    Next AbstractMultimodal cues drive host-plant assessment in Asian citrus psyllid (Diaphorina citri) »

Health Rep


Title:Implementation of the indoor air component of cycle 2 of the Canadian Health Measures Survey
Author(s):Patry-Parisien J; Wong SL; Zhu J;
Address:"Health Statistics Division, Statistics Canada, Ottawa, Ontario, K1A 0T6. jennifer.patry-parisien@statcan.gc.ca"
Journal Title:Health Rep
Year:2013
Volume:24
Issue:5
Page Number:3 - 10
DOI:
ISSN/ISBN:1209-1367 (Electronic) 0840-6529 (Linking)
Abstract:"BACKGROUND: The presence of volatile organic compounds (VOCs) in indoor air may have negative health consequences, ranging from mild irritation to more severe illnesses. Indoor air data are required to assess Canadian population exposure to these VOCs. DATA AND METHODS: The 2009 to 2011 Canadian Health Measures Survey (CHMS) included an indoor air component. Respondents who went to the mobile examination centre to participate in the physical measures section of the survey were asked to deploy an indoor air sampler in their homes for 7 consecutive days. Data were collected for 84 VOCs. Control samples that were implemented included duplicates and blanks. RESULTS: Of the 4,686 indoor air samplers given to CHMS respondents, 4,581 were deployed and returned to the testing laboratory. Data from 3,857 samplers met the criteria for inclusion in the CHMS indoor air data files. Thirteen VOCs had a mean percentage difference between the duplicate pairs greater than 30%. The field and cleaning blank geometric means and medians were lower than 1 mug/m(3) for 83 VOCs. INTERPRETATION: The high percentage of mobile examination centre participants who deployed samplers in their homes, the sampler return rate, and the quality of the data obtained demonstrate the feasibility of relying on respondents to handle indoor air samplers for large-scale collection of residential VOC data"
Keywords:"*Air Pollutants *Air Pollution, Indoor Canada Health Surveys Humans Volatile Organic Compounds air pollution air quality data collection indoor air sampler organic chemicals survey methods;"
Notes:"MedlinePatry-Parisien, Jennifer Wong, Suzy L Zhu, Jiping eng Canada 2013/11/22 Health Rep. 2013 May; 24(5):3-10"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024