Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractMicroclimatic variation within sleeve cages used in ecological studies    Next AbstractMediation of a plant-spider association by specific volatile compounds »

Anal Bioanal Chem


Title:Metrological approaches to organic chemical purity: primary reference materials for vitamin D metabolites
Author(s):Nelson MA; Bedner M; Lang BE; Toman B; Lippa KA;
Address:"Material Measurement Laboratory, Chemical Sciences Division, National Institute of Standards and Technology, Gaithersburg, MD, 20899-8392, USA. michael.nelson@nist.gov. Material Measurement Laboratory, Chemical Sciences Division, National Institute of Standards and Technology, Gaithersburg, MD, 20899-8392, USA. Material Measurement Laboratory, Biosystems and Biomaterials Division, National Institute of Standards and Technology, Gaithersburg, MD, 20899-8392, USA. Information Technology Laboratory, Statistical Engineering Division, National Institute of Standards and Technology, Gaithersburg, MD, 20899-8392, USA"
Journal Title:Anal Bioanal Chem
Year:2015
Volume:20150907
Issue:28
Page Number:8557 - 8569
DOI: 10.1007/s00216-015-9013-7
ISSN/ISBN:1618-2650 (Electronic) 1618-2642 (Linking)
Abstract:"Given the critical role of pure, organic compound primary reference standards used to characterize and certify chemical Certified Reference Materials (CRMs), it is essential that associated mass purity assessments be fit-for-purpose, represented by an appropriate uncertainty interval, and metrologically sound. The mass fraction purities (% g/g) of 25-hydroxyvitamin D (25(OH)D) reference standards used to produce and certify values for clinical vitamin D metabolite CRMs were investigated by multiple orthogonal quantitative measurement techniques. Quantitative (1)H-nuclear magnetic resonance spectroscopy (qNMR) was performed to establish traceability of these materials to the International System of Units (SI) and to directly assess the principal analyte species. The 25(OH)D standards contained volatile and water impurities, as well as structurally-related impurities that are difficult to observe by chromatographic methods or to distinguish from the principal 25(OH)D species by one-dimensional NMR. These impurities have the potential to introduce significant biases to purity investigations in which a limited number of measurands are quantified. Combining complementary information from multiple analytical methods, using both direct and indirect measurement techniques, enabled mitigation of these biases. Purities of 25(OH)D reference standards and associated uncertainties were determined using frequentist and Bayesian statistical models to combine data acquired via qNMR, liquid chromatography with UV absorbance and atmospheric pressure-chemical ionization mass spectrometric detection (LC-UV, LC-ACPI-MS), thermogravimetric analysis (TGA), and Karl Fischer (KF) titration"
Keywords:"Bayes Theorem Chromatography, Liquid/methods/*standards Magnetic Resonance Spectroscopy/methods/*standards Mass Spectrometry/methods/*standards Reference Standards Solutions Thermogravimetry Vitamin D/analogs & derivatives/*isolation & purification Data c;"
Notes:"MedlineNelson, Michael A Bedner, Mary Lang, Brian E Toman, Blaza Lippa, Katrice A eng Research Support, N.I.H., Extramural Germany 2015/09/09 Anal Bioanal Chem. 2015 Nov; 407(28):8557-69. doi: 10.1007/s00216-015-9013-7. Epub 2015 Sep 7"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 01-07-2024