Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractInformation theory tests critical predictions of plant defense theory for specialized metabolism    Next Abstract"Artificial Light Pollution with Different Wavelengths at Night Interferes with Development, Reproduction, and Antipredator Defenses of Daphnia magna" »

Analyst


Title:A flexible virtual sensor array based on laser-induced graphene and MXene for detecting volatile organic compounds in human breath
Author(s):Li D; Shao Y; Zhang Q; Qu M; Ping J; Fu Y; Xie J;
Address:"State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, Zhejiang 310027, China. xiejin@zju.edu.cn. Laboratory of Agricultural Information Intelligent Sensing, School of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, Zhejiang 310058, China. Faculty of Engineering and Environment, University of Northumbria, Newcastle upon Tyne NE1 8ST, UK"
Journal Title:Analyst
Year:2021
Volume:20210913
Issue:18
Page Number:5704 - 5713
DOI: 10.1039/d1an01059j
ISSN/ISBN:1364-5528 (Electronic) 0003-2654 (Linking)
Abstract:"Detecting volatile organic compounds (VOCs) in human breath is critical for the early diagnosis of diseases. Good selectivity of VOC sensors is crucial for the accurate analysis of VOC biomarkers in human breath, which consists of more than 200 types of VOCs. In this paper, a flexible virtual sensor array (FVSA) was proposed based on a sensing layer of MXene and laser-induced graphene interdigital electrodes (LIG-IDEs) for detecting VOCs in exhaled human breath. The fabrication of LIG-IDEs avoids the costly and complicated procedures required for the preparation of traditional IDEs. The FVSA's responses of multiple parameters help build a unique fingerprint for each VOC, without a need for changing the temperature of the sensing element, which is commonly used in the VSA of semiconductor VOC sensors. Based on machine learning algorithms, we have achieved highly precise recognition of different VOCs and mixtures and accurate prediction (accuracy of 89.1%) of the objective VOC's concentration in variable backgrounds using this proposed FVSA. Moreover, a blind analysis validates the capacity of the FVSA to identify alcohol content in human breath with an accuracy of 88.9% using breath samples from volunteers before and after alcohol consumption. These results show that the proposed FVSA is promising for the detection of VOC biomarkers in human exhaled breath and early diagnosis of diseases"
Keywords:Biomarkers Breath Tests *Graphite Humans Lasers *Volatile Organic Compounds;
Notes:"MedlineLi, Dongsheng Shao, Yuzhou Zhang, Qian Qu, Mengjiao Ping, Jianfeng Fu, YongQing Xie, Jin eng England 2021/09/14 Analyst. 2021 Sep 13; 146(18):5704-5713. doi: 10.1039/d1an01059j"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 03-07-2024