Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractFlexible TPU inverse opal fabrics for colorimetric detecting of VOCs    Next Abstract"Ligand-interaction kinetics of the pheromone- binding protein from the gypsy moth, L. dispar: insights into the mechanism of binding and release" »

Anal Chem


Title:Development and application of a needle trap device for time-weighted average diffusive sampling
Author(s):Gong Y; Eom IY; Lou DW; Hein D; Pawliszyn J;
Address:"Department of Chemistry, University of Waterloo, Waterloo, Ontario, N2L 3G1 Canada"
Journal Title:Anal Chem
Year:2008
Volume:20080903
Issue:19
Page Number:7275 - 7282
DOI: 10.1021/ac800884f
ISSN/ISBN:1520-6882 (Electronic) 0003-2700 (Linking)
Abstract:"A simple, cost-effective analysis combining solventless extraction, thermal desorption, and determination of volatile organic compounds (VOCs) was developed and validated. A needle trap device (NTD) packed with the sorbent Carboxen1000 was used as a time-weighted average (TWA) diffusive sampler to collect target compounds by molecular diffusion and adsorption to the packed sorbent. This process can be described with derivations of Fick's first law of diffusion, which expresses the relation between the TWA concentrations to which the passive sampler is exposed and the mass of analytes adsorbed to the packed sorbent in the sampler. The effects of experimental factors such as temperature, pressure, humidity, and face velocity were taken into account in applying diffusive sampling under nonideal conditions. This study demonstrates that NTD is effective for air analysis of benzene, toluene, ethylbenzene, and o-xylene (BTEX), due to the good adsorption/desorption quality of Carboxen 1000 and to the special geometric shape of the needle with a small cross section avoiding the need for calibration. Storage tests showed good storage stability for BTEX. Verification of the theoretical model showed good agreement between theoretical and experimental sampling rates. Method validation done against NIOSH method 1501, SPME, and NTD active sampling revealed good agreement between those methods. Automated NTD sample introduction to a gas chromatograph facilitates the use of this technology for industrial hygiene applications"
Keywords:
Notes:"PubMed-not-MEDLINEGong, Ying Eom, In-Yong Lou, Da-Wei Hein, Dietmar Pawliszyn, Janusz eng 2008/09/04 Anal Chem. 2008 Oct 1; 80(19):7275-82. doi: 10.1021/ac800884f. Epub 2008 Sep 3"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024