Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractDirect inhibition of (Z)-9 desaturation of (E)-11-tetradecenoic acid by methylenehexadecenoic acids in the biosynthesis of Spodoptera littoralis sex pheromone    Next AbstractChemical-Sensory Traits of Fresh Cheese Made by Enzymatic Coagulation of Donkey Milk »

Anal Bioanal Chem


Title:Occupational exposure to complex mixtures of volatile organic compounds in ambient air: desorption from activated charcoal using accelerated solvent extraction can replace carbon disulfide?
Author(s):Fabrizi G; Fioretti M; Rocca LM;
Address:"Occupational Hygiene Department, Chemical Agents Laboratory, Italian Workers' Compensation Authority (INAIL)-Research Area, Rome, Italy. g.fabrizi@inail.it"
Journal Title:Anal Bioanal Chem
Year:2013
Volume:20120912
Issue:2-Mar
Page Number:961 - 976
DOI: 10.1007/s00216-012-6379-7
ISSN/ISBN:1618-2650 (Electronic) 1618-2642 (Linking)
Abstract:"A desorption study of 57 volatile organic compounds (VOCs) has been conducted by use of accelerated solvent extraction (ASE) and gas chromatography-mass spectrometry. Different solvents were tested to extract activated charcoal tubes with the objective of replacing carbon disulfide, used in official methods, because of its highly toxic health and environmental effects. Extraction conditions, for example temperature and number of cycles, were investigated and optimized. The definitive extraction procedure selected was use of acetone at 150 degrees C and two consecutive extraction cycles at a pressure of 1,500 psi. Considering a sample volume of 0.005 Nm(3), corresponding to a sampling time of 8 h at a flow rate of 0.01 L min(-1), the method was validated over the concentration range 65-26,300 mug Nm(-3). The lowest limit of quantification was 6 mug Nm(-3), and recovery for the 93 % of analytes ranged from 65 to 102 %. For most of the compounds, relative standard deviations were less than 15 % for inter and intra-day precision. Uncertainty of measurement was also determined: the relative expanded uncertainty was always below 29.6 %, except for dichlorodifluoromethane. This work shows that use of friendlier solvent, for example acetone, coupled with use of ASE, can replace use of CS(2) for chemical removal of VOCs from activated charcoal. ASE has several advantages over traditional solvent-extraction methods, including shorter extraction time, minimum sample manipulation, high reproducibility, and less extraction discrimination. No loss of sensitivity occurs and there is also a salutary effect on bench workers' health and on the smell of laboratory air"
Keywords:Adsorption Air Pollutants/*analysis/*isolation & purification Carbon Disulfide/chemistry Charcoal/*chemistry Gas Chromatography-Mass Spectrometry Occupational Exposure Solid Phase Extraction/instrumentation/*methods Temperature Volatile Organic Compounds/;
Notes:"MedlineFabrizi, Giovanni Fioretti, Marzia Rocca, Lucia Mainero eng Evaluation Study Germany 2012/09/13 Anal Bioanal Chem. 2013 Jan; 405(2-3):961-76. doi: 10.1007/s00216-012-6379-7. Epub 2012 Sep 12"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024