Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractOnline Volatile Compound Emissions Analysis Using a Microchamber/Thermal Extractor Coupled to Proton Transfer Reaction-Mass Spectrometry    Next AbstractTracking Airborne Molecules from Afar: Three-Dimensional Metal-Organic Framework-Surface-Enhanced Raman Scattering Platform for Stand-Off and Real-Time Atmospheric Monitoring »

Chem Res Toxicol


Title:Volatile Compound Emissions from Stereolithography Three-Dimensional Printed Cured Resin Models for Biomedical Applications
Author(s):Pham YL; Wojnowski W; Beauchamp J;
Address:"Department of Sensory Analytics and Technologies, Fraunhofer Institute for Process Engineering and Packaging IVV, Giggenhauser Strasse 35, 85354Freising, Germany. Department of Chemistry and Pharmacy, Chair of Aroma and Smell Research, Friedrich-Alexander-Universitat Erlangen-Nurnberg, Henkestrasse 9, 91054Erlangen, Germany. Department of Analytical Chemistry, Faculty of Chemistry, Gdansk University of Technology, 11/12 Narutowicza Street, 80-233Gdansk, Poland. Department of Chemistry, University of Oslo, P.O. Box 1033-Blindern, 0315Oslo, Norway"
Journal Title:Chem Res Toxicol
Year:2023
Volume:20221219
Issue:3
Page Number:369 - 379
DOI: 10.1021/acs.chemrestox.2c00317
ISSN/ISBN:1520-5010 (Electronic) 0893-228X (Linking)
Abstract:"Stereolithography three-dimensional printing is used increasingly in biomedical applications to create components for use in healthcare and therapy. The exposure of patients to volatile organic compounds (VOCs) emitted from cured resins represents an element of concern in such applications. Here, we investigate the biocompatibility in relation to inhalation exposure of volatile emissions of three different cured commercial resins for use in printing a mouthpiece adapter for sampling exhaled breath. VOC emission rates were estimated based on direct analysis using a microchamber/thermal extractor coupled to a proton transfer reaction-mass spectrometer. Complementary analyses using comprehensive gas chromatography-mass spectrometry aided compound identification. Major VOCs emitted from the cured resins were associated with polymerization agents, additives, and postprocessing procedures and included alcohols, aldehydes, ketones, hydrocarbons, esters, and terpenes. Total VOC emissions from cubes printed using the general-purpose resin were approximately an order of magnitude higher than those of the cubes printed using resins dedicated to biomedical applications at the respective test temperatures (40 and 25 degrees C). Daily inhalation exposures were estimated and compared with daily tolerable intake levels or standard thresholds of toxicological concerns. The two resins intended for biomedical applications were deemed suitable for fabricating an adapter mouthpiece for use in breath research. The general-purpose resin was unsuitable, with daily inhalation exposures for breath sampling applications at 40 degrees C estimated at 310 mug day(-1) for propylene glycol (tolerable intake (TI) limit of 190 mug day(-1)) and 1254 mug day(-1) for methyl acrylate (TI of 43 mug day(-1))"
Keywords:Humans *Volatile Organic Compounds/analysis Stereolithography Gas Chromatography-Mass Spectrometry Mass Spectrometry Hydrocarbons/analysis;
Notes:"MedlinePham, Y Lan Wojnowski, Wojciech Beauchamp, Jonathan eng Research Support, Non-U.S. Gov't 2022/12/20 Chem Res Toxicol. 2023 Mar 20; 36(3):369-379. doi: 10.1021/acs.chemrestox.2c00317. Epub 2022 Dec 19"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024