Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractSimulated herbivory does not constrain phenotypic plasticity to shade through ontogeny in a relict tree    Next AbstractTestosterone augments neuronal Fos responses to estrous odors throughout the vomeronasal projection pathway of gonadectomized male and female rats »

J Chromatogr A


Title:Single-injection calibration approach for high-performance liquid chromatography
Author(s):Paredes E; Maestre SE; Prats MS; Todoli JL;
Address:"Department of Analytical Chemistry, Nutrition and Food Sciences, University of Alicante, 03080 Alicante, Spain"
Journal Title:J Chromatogr A
Year:2008
Volume:20080131
Issue:2
Page Number:178 - 184
DOI: 10.1016/j.chroma.2008.01.071
ISSN/ISBN:0021-9673 (Print) 0021-9673 (Linking)
Abstract:"A new calibration method for high-performance liquid chromatography was validated. The method was called single-injection calibration approach (SICA) because it allowed to obtain a complete calibration curve by means of a single injection of a standard solution containing several non-volatile and semi-volatile organic compounds at different concentration levels. The compounds studied included carboxylic acids, polyalcohols, carbohydrates and water-soluble vitamins. This method allowed a 1-7-fold reduction in the analysis time with regard to conventional calibration methods. The method was applied to three different chromatographic detection methods: refractive index (RI) detection, diode array detection (DAD) and inductively coupled plasma atomic emission detection (ICP-AED). Good linearity was achieved (r(2)>0.999) for the three detection methods but signal correction was required for RI detection and DAD. This fact demonstrated that ICP-AES was the most universal because the signal obtained for non-volatile and semi-volatile organic compounds was not a function of the chemical nature of the compound and only depended on the mass content of carbon. The method was validated by analyzing a reference non-fat milk powder sample as well as several real food samples (three fruit juices, four wines, three candies and a multivitamin complex)"
Keywords:"Calibration Chromatography, High Pressure Liquid/*methods Food Analysis/*methods Organic Chemicals/*analysis;"
Notes:"MedlineParedes, Eduardo Maestre, Salvador E Prats, Ma Soledad Todoli, Jose L eng Research Support, Non-U.S. Gov't Validation Study Netherlands 2008/02/27 J Chromatogr A. 2008 Mar 28; 1185(2):178-84. doi: 10.1016/j.chroma.2008.01.071. Epub 2008 Jan 31"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 28-12-2024