Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractVolatile compounds in whole meal bread crust: The effects of yeast level and fermentation temperature    Next Abstract"Volatile organic compounds (VOC), formaldehyde and nitrogen dioxide (NO(2)) in schools in Johor Bahru, Malaysia: Associations with rhinitis, ocular, throat and dermal symptoms, headache and fatigue" »

Br J Ind Med


Title:"Volatile organic compounds, respirable dust, and personal factors related to prevalence and incidence of sick building syndrome in primary schools"
Author(s):Norback D; Torgen M; Edling C;
Address:"Department of Occupational Medicine, University Hospital, Uppsala, Sweden"
Journal Title:Br J Ind Med
Year:1990
Volume:47
Issue:11
Page Number:733 - 741
DOI: 10.1136/oem.47.11.733
ISSN/ISBN:0007-1072 (Print) 0007-1072 (Linking)
Abstract:"Possible relations between incidence and prevalence of sick building syndrome (SBS), indoor exposures, and personal factors were studied in a four year longitudinal study among personnel (n = 129) in six primary schools. The mean concentration of carbon dioxide was above the recommended value of 0.08 microliter/l (800 ppm) in all schools, indicating a poor outdoor air supply. Indoor concentration of volatile hydrocarbon (VOC) was enhanced at high room temperatures. Respirable dust, but not concentration of VOC was enhanced at lower ventilation rates and high air humidity. Chronic SBS was related to VOC, previous wall to wall carpeting in the schools, hyper-reactivity, and psychosocial factors. Incidence of new SBS was related to concentration of respirable dust, current smoking, and the psychosocial climate. Remission of hyperreactivity, decrease in sick leave owing to airway illness, removal of carpeting in the schools, and moving from new to old dwellings resulted in a decrease in SBS score. It is concluded that SBS is of multifactorial origin, related to a variety of factors and exposures. The total concentration of hydrocarbons is a simple and convenient measure of exposure, which also seems to be a predictor of chronic symptoms. Further investigations on the effect of temperature, ventilation, and air humidity on SBS should consider how these factors may influence the chemical composition of the air. Because poor air quality in schools could also affect the children, it may have implications for the state of health of a large proportion of the population"
Keywords:Carbon Dioxide/adverse effects Chronic Disease Dust/adverse effects *Environmental Exposure Female Humans Humidity/adverse effects Hydrocarbons/adverse effects Incidence Longitudinal Studies Male Occupational Diseases/*epidemiology Prevalence *Schools Tem;
Notes:"MedlineNorback, D Torgen, M Edling, C eng England 1990/11/01 Br J Ind Med. 1990 Nov; 47(11):733-41. doi: 10.1136/oem.47.11.733"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024