Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractDietary lufenuron reduces egg hatch and influences protein expression in the fruit fly Bactrocera latifrons (Hendel)    Next AbstractAssessment of control strategies for reducing volatile organic compound emissions from the polyvinyl chloride wallpaper production industry in Taiwan »

Ann Occup Hyg


Title:Comparison between Thermal Desorption Tubes and Stainless Steel Canisters Used for Measuring Volatile Organic Compounds in Petrochemical Factories
Author(s):Chang CP; Lin TC; Lin YW; Hua YC; Chu WM; Lin TY; Lin YW; Wu JD;
Address:"1.Department of Occupational Safety and Health, Chang Jung Christian University, Tainan 71101, Taiwan; 2.Occupational Hygiene Association of Taiwan, New Taipei City 24205, Taiwan; 2.Occupational Hygiene Association of Taiwan, New Taipei City 24205, Taiwan; 3.Department of Safety, Health and Environmental Engineering, National United University, Lienda, Miaoli 36063, Taiwan; 2.Occupational Hygiene Association of Taiwan, New Taipei City 24205, Taiwan; 4.Department of Public Health, Fu Jen Catholic University, New Taipei City 24205, Taiwan. 3.Department of Safety, Health and Environmental Engineering, National United University, Lienda, Miaoli 36063, Taiwan; 1.Department of Occupational Safety and Health, Chang Jung Christian University, Tainan 71101, Taiwan; 1.Department of Occupational Safety and Health, Chang Jung Christian University, Tainan 71101, Taiwan; 2.Occupational Hygiene Association of Taiwan, New Taipei City 24205, Taiwan; jdwu@mail.cjcu.edu.com"
Journal Title:Ann Occup Hyg
Year:2016
Volume:20151118
Issue:3
Page Number:348 - 360
DOI: 10.1093/annhyg/mev078
ISSN/ISBN:1475-3162 (Electronic) 0003-4878 (Print) 0003-4878 (Linking)
Abstract:"OBJECTIVE: The purpose of this study was to compare thermal desorption tubes and stainless steel canisters for measuring volatile organic compounds (VOCs) emitted from petrochemical factories. METHODS: Twelve petrochemical factories in the Mailiao Industrial Complex were recruited for conducting the measurements of VOCs. Thermal desorption tubes and 6-l specially prepared stainless steel canisters were used to simultaneously perform active sampling of environmental air samples. The sampling time of the environmental air samples was set up on 6 h close to a full work shift of the workers. A total of 94 pairwise air samples were collected by using the thermal adsorption tubes and stainless steel canisters in these 12 factories in the petrochemical industrial complex. To maximize the number of comparative data points, all the measurements from all the factories in different sampling times were lumped together to perform a linear regression analysis for each selected VOC. Pearson product-moment correlation coefficient was used to examine the correlation between the pairwise measurements of these two sampling methods. A paired t-test was also performed to examine whether the difference in the concentrations of each selected VOC measured by the two methods was statistically significant. RESULTS: The correlation coefficients of seven compounds, including acetone, n-hexane, benzene, toluene, 1,2-dichloroethane, 1,3-butadiene, and styrene were >0.80 indicating the two sampling methods for these VOCs' measurements had high consistency. The paired t-tests for the measurements of n-hexane, benzene, m/p-xylene, o-xylene, 1,2-dichloroethane, and 1,3-butadiene showed statistically significant difference (P-value < 0.05). This indicated that the two sampling methods had various degrees of systematic errors. Looking at the results of six chemicals and these systematic errors probably resulted from the differences of the detection limits in the two sampling methods for these VOCs. CONCLUSIONS: The comparison between the concentrations of each of the 10 selected VOCs measured by the two sampling methods indicted that the thermal desorption tubes provided high accuracy and precision measurements for acetone, benzene, and 1,3-butadiene. The accuracy and precision of using the thermal desorption tubes for measuring the VOCs can be improved due to new developments in sorbent materials, multi-sorbent designs, and thermal desorption instrumentation. More applications of thermal desorption tubes for measuring occupational and environmental hazardous agents can be anticipated"
Keywords:Acetone/analysis Air Pollutants/analysis Benzene/analysis Butadienes/analysis Chemical Industry Environmental Monitoring/*instrumentation/methods Hazardous Substances/analysis Humans Occupational Exposure/analysis *Stainless Steel Volatile Organic Compoun;
Notes:"MedlineChang, Cheng-Ping Lin, Tser-Cheng Lin, Yu-Wen Hua, Yi-Chun Chu, Wei-Ming Lin, Tzu-Yu Lin, Yi-Wen Wu, Jyun-De eng Comparative Study Research Support, Non-U.S. Gov't England 2015/11/21 Ann Occup Hyg. 2016 Apr; 60(3):348-60. doi: 10.1093/annhyg/mev078. Epub 2015 Nov 18"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024