Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractUtilization of activated carbon as an effective replacement for a commercialized three-bed sorbent (Carbopack) to quantitate aromatic hydrocarbons in ambient air    Next Abstract"Preliminary quantification of the permeability, solubility and diffusion coefficients of major aroma compounds present in herbs through various plastic packaging materials" »

ACS Appl Mater Interfaces


Title:Photomechanical and Chemomechanical Actuation Behavior of Graphene-Poly(dimethylsiloxane)/Gold Bilayer Tube for Multimode Soft Grippers and Volatile Organic Compounds Detection Applications
Author(s):Leeladhar; Singh JP;
Address:"Department of Physics , Indian Institute of Technology Delhi , Hauz Khas, New Delhi 110016 , India. Solid State Physics Laboratory , Lucknow Road , Timarpur, Delhi 110054 , India"
Journal Title:ACS Appl Mater Interfaces
Year:2018
Volume:20180925
Issue:40
Page Number:33956 - 33965
DOI: 10.1021/acsami.8b11440
ISSN/ISBN:1944-8252 (Electronic) 1944-8244 (Linking)
Abstract:"Graphene polymers-based soft actuators driven by infrared (IR) light have attracted wide attention recently. However, the scientific fraternity is striving hard in unraveling the area of actuators that could be triggered by IR light along with chemicals. The fabricating methodology of multiresponsive soft actuators based on graphene nanoplatelets (GNPs)-poly(dimethylsiloxane) (PDMS) nanocomposite/gold bilayers, ensuring large, fast, and reversible response, has been illustrated. The actuators display a novel dual-mode operation as photomechanical and chemomechanical actuation. The actuators are realized by depositing a thin film (100 nm) of gold on GNP-PDMS nanocomposite films resulting tubular structure on account of thermal residual stress. The actuation response of this structure upon its exposure to IR light and chemicals was measured in terms of percentage opening and degree of unscroll, respectively. The three-dimensional tubular structure is transformed into a two-dimensional sheet within 8 s under IR light irradiation. The same structures were also tested in various organic solvents like methanol, ethanol, acetone, isopropyl alcohol, and aldehydes, but the actuation has been observed only in acetone and aldehydes. This tubular actuator unscrolls completely and then scrolls in opposite direction along with tube axis shift through 90 degrees during its exposure to acetone (liquid/vapors) and aldehydes. Few applications of these actuators, such as multimode soft grippers for on-demand capture/release of objects (with weight 1.2 times the actuator's own weight) and volatile organic compounds detection module, have been demonstrated. The combination of surface micromachining techniques of microelectromechanical systems process with this smart material may find applications in drug-delivery systems with precise control, soft robotics, and noninvasive diagnosis of diabetes and breast/lung cancers"
Keywords:Dimethylpolysiloxanes/*chemistry Gold/*chemistry Graphite/*chemistry *Infrared Rays Nanoparticles/*chemistry Volatile Organic Compounds/*analysis chemomechanical actuators graphene nanoplatelets nanocomposite photomechanical actuators poly(dimethylsiloxan;
Notes:"MedlineLeeladhar Singh, J P eng 2018/09/27 ACS Appl Mater Interfaces. 2018 Oct 10; 10(40):33956-33965. doi: 10.1021/acsami.8b11440. Epub 2018 Sep 25"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024