Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractIndole primes defence signalling and increases herbivore resistance in tea plants    Next AbstractMixing of secondary organic aerosols versus relative humidity »

J Chromatogr A


Title:Development of solid-phase microextraction followed by gas chromatography-mass spectrometry for rapid analysis of volatile organic chemicals in mainstream cigarette smoke
Author(s):Ye Q;
Address:"Department of Chemistry, Shangrao Normal University, Shangrao 334001, Province of Jiangxi, China. sryq6333@163.com"
Journal Title:J Chromatogr A
Year:2008
Volume:20081021
Issue:2
Page Number:239 - 244
DOI: 10.1016/j.chroma.2008.10.063
ISSN/ISBN:0021-9673 (Print) 0021-9673 (Linking)
Abstract:"In this work, a novel, simple and efficient method based on solid-phase microextraction (SPME) followed by gas chromatography-mass spectrometry (GC-MS) was developed to the analysis of volatile organic chemicals (VOCs) in mainstream cigarette smoke (MCS). Using a simple home-made smoking machine device, extraction and concentration of VOCs in MCS were performed by SPME fiber, and the VOCs adsorbed on fiber were desorbed, and analyzed by GC-MS. The extraction fiber types and the desorption conditions were studied, and the method precision was also investigated. After the investigation, the optimal fiber was divinylbenzene/carboxen/polydemethylsiloxane (DVB/CAR/PDMS), and the optimal desorption condition was 250 degrees C for 3 min. The method precision was from 2% to 11%. Finally, the proposed method was tested by its application of the analysis of VOCs in MCS from 10 brands of cigarettes and one reference cigarette. A total of 70 volatile compounds were identified by the proposed method. The experimental results showed that the proposed method was a simple, rapid, reliable, and solvent-free technique for the determination of VOCs in MCS"
Keywords:"Air Pollution, Indoor/analysis Gas Chromatography-Mass Spectrometry/methods Smoke/analysis Solid Phase Microextraction/methods Tobacco/*chemistry Volatile Organic Compounds/*analysis;"
Notes:"MedlineYe, Qing eng Netherlands 2008/11/11 J Chromatogr A. 2008 Dec 12; 1213(2):239-44. doi: 10.1016/j.chroma.2008.10.063. Epub 2008 Oct 21"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024