Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractExpression and secretion of glucoamylase of Aspergillus niger in Saccharomyces cerevisiae    Next AbstractDetermination of volatile organic compounds exhaled by cell lines derived from hematological malignancies »

ScientificWorldJournal


Title:A comparison study of sampling and analyzing volatile organic compounds in air in Kuwait by using Tedlar bags/canisters and GC-MS with a cryogenic trap
Author(s):Tang H; Beg KR; Al-Otaiba Y;
Address:"Urban and Environment Division, Coastal and Air Pollution Department, Kuwait Institute for Scientific Research, P.O. Box 24885, 13109 Safat, Kuwait. htang@safat.kisr.edu.kw"
Journal Title:ScientificWorldJournal
Year:2006
Volume:20060512
Issue:
Page Number:551 - 562
DOI: 10.1100/tsw.2006.111
ISSN/ISBN:1537-744X (Electronic) 2356-6140 (Print) 1537-744X (Linking)
Abstract:"Kuwait experiences desert climatic weather. Due to the extreme hot and dry conditions in this country, some analytical phenomena have been discovered. Therefore, a systematic study of sampling and analyzing volatile organic compounds in air by using GC-MS with a cryogenic trap is reported in this paper. This study included comparisons of using different sample containers such as Tedlar bags and SUMMA canisters, and different cryogenic freezing-out air volumes in the trap. Calibration curves for different compounds and improvement of replicated analysis results were also reported here. The study found that using different sample containers produced different results. Analysis of ambient air samples collected in Tedlar bags obtained several volatile organic compounds with large concentrations compared to using SUMMA canisters. Therefore, to choose a sample container properly is a key element for successfully completing a project. Because GC-MS with a cryogenic trap often generates replicated results with poor agreement, an internal standard added to gas standards and air samples by using a gas syringe was tested. The study results proved that it helped to improve the replicated results"
Keywords:"Air Pollutants/*analysis Calibration Chemistry Techniques, Analytical Environmental Monitoring/*instrumentation/*methods Equipment Design Gas Chromatography-Mass Spectrometry/*methods Kuwait Reproducibility of Results Specimen Handling Volatilization;"
Notes:"MedlineTang, Hongmao Beg, Khaliq R Al-Otaiba, Yousef eng Comparative Study 2006/05/16 ScientificWorldJournal. 2006 May 12; 6:551-62. doi: 10.1100/tsw.2006.111"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024