Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractA new genus and species of Placusini from a high mountain in Mexico    Next AbstractFlight Phenology of Elasmopalpus lignosellus (Lepidoptera: Pyralidae) in the Northwest Florida Panhandle »

Appl Microbiol Biotechnol


Title:Conversion of chemical scrubbers to biotrickling filters for VOCs and H2S treatment at low contact times
Author(s):Santos A; Guimera X; Dorado AD; Gamisans X; Gabriel D;
Address:"Department of Chemical Engineering, School of Engineering, Universitat Autonoma de Barcelona, 08193, Bellaterra, Spain"
Journal Title:Appl Microbiol Biotechnol
Year:2015
Volume:20140516
Issue:1
Page Number:67 - 76
DOI: 10.1007/s00253-014-5796-2
ISSN/ISBN:1432-0614 (Electronic) 0175-7598 (Linking)
Abstract:"The purpose of this work was to evaluate the technical and economical feasibility of converting three chemical scrubbers in series to biotrickling filters (BTFs) for the simultaneous removal of H2S and volatile organic compounds (VOCs). The conversion of the full-scale scrubbers was based on previous conversion protocols. Conversion mainly required replacing the original carrier material and recycle pumps as well as modifying the controls and operation of the reactors. Complete removal of H2S and VOCs on a routine basis was reached at neutral pH in a longer period of time compared to previous conversions reported. Biotrickling filters operated at a gas contact time of about 1.4 s per reactor and at pH controlled between 6.5 and 6.8. Inlet average concentrations below 10 ppmv of H2S and below 5 ppmv for VOCs were often completely removed. The first and second bioreactors played a primary role in H2S removal. Year-round operation of the biotrickling filters proved the ability of the system to handle progressive load increases of H2S and VOCs. However, fast, sudden load changes often lead to reduced removal efficiencies. Odor analyses showed average removal efficiencies above 80%. Gas chromatography-mass spectrometry of selected samples showed that outlet odor concentration was due to limited removal of VOCs. The conversion showed was economically viable taking into account the theoretical consumption of chemicals needed for the absorption and oxidation of both H2S and VOCs"
Keywords:*Air Filters Bioreactors/*microbiology Filtration/*methods Gas Chromatography-Mass Spectrometry Hydrogen Sulfide/*metabolism Hydrogen-Ion Concentration Odorants/analysis Volatile Organic Compounds/*metabolism;
Notes:"MedlineSantos, Alfredo Guimera, Xavier Dorado, Antonio David Gamisans, Xavier Gabriel, David eng Research Support, Non-U.S. Gov't Germany 2014/05/17 Appl Microbiol Biotechnol. 2015 Jan; 99(1):67-76. doi: 10.1007/s00253-014-5796-2. Epub 2014 May 16"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024