Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractAssessment of environmental and ergonomic hazard associated to printing and photocopying: a review    Next AbstractGenome analysis uncovers the prolific antagonistic and plant growth-promoting potential of endophyte Bacillus velezensis K1 »

Environ Geochem Health


Title:Estimation of indoor air pollutant during photocopy/printing operation: a computational fluid dynamics (CFD)-based study
Author(s):Nandan A; Siddiqui NA; Kumar P;
Address:"University of Petroleum and Energy Studies, Dehradun, India. abhisheknandan24@gmail.com. University of Petroleum and Energy Studies, Dehradun, India"
Journal Title:Environ Geochem Health
Year:2020
Volume:20200513
Issue:11
Page Number:3543 - 3573
DOI: 10.1007/s10653-020-00589-0
ISSN/ISBN:1573-2983 (Electronic) 0269-4042 (Linking)
Abstract:"Population form a homeostat with environment where they live and exchange continuous gas for their respiration, which is the primary pathway for the pollutants to enter into human metabolism. The pollution present indoor is due to multiple sources like electronic and electrical equipment, clothes, furniture and other anthropogenic activity. The concentration of these pollutants changes with time and depends mainly on source type (continuous/intermittent), time of the operation and release/ventilation/wind velocity/pollutant dispersion and anthropogenic activity. It has been observed that equipment like printers, printing machines, photocopiers, etc., releases several pollutants like volatile organic compounds (VOCs), ozone (O(3)), semi-volatile organic compounds, benzene (C(6)H(6)), toluene and suspended particulate matter during operation. This work represents the emissions of VOCs, benzene, and toluene during photocopy. The numerical validation of results was done using Fluent, which is an application-based software which helps in physical modeling describing air flow and effect of multiple parameter on it like temperature and no of printing/photocopy (in proposed experiment) with respect to time. It has been observed from the results that the emissions of VOCs, benzene, and toluene increase from 0.09 to 1.13 PPM, 0.17 to 1.87 PPM and 30 to 235 PPM, respectively, as the operating duration, temperature (35-40 degrees C) and rate of printing/photocopying increase (120-200/h), and it is because printer/photocopy machine uses heat and pressure to fix an image on the paper surface which subsequently result in higher emission. Multiple adverse health, safety and environmental impacts due to operation of photocopy/printing call for in-depth study, guidance, and monitoring of the workers occupationally associated with this operation for their well-being"
Keywords:"Air Pollutants/analysis Air Pollution, Indoor/*analysis Benzene/analysis *Copying Processes Humans Hydrodynamics Occupational Exposure Particulate Matter/analysis Software Toluene/analysis Volatile Organic Compounds/*analysis Indoor air pollution Occupati;"
Notes:"MedlineNandan, Abhishek Siddiqui, Nihal Anwar Kumar, Pankaj eng Netherlands 2020/05/15 Environ Geochem Health. 2020 Nov; 42(11):3543-3573. doi: 10.1007/s10653-020-00589-0. Epub 2020 May 13"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024