« Previous AbstractInfluence of storage on volatile profiles in roasted almonds (Prunus dulcis)    Next AbstractEmploying CO(2) as reaction medium for in-situ suppression of the formation of benzene derivatives and polycyclic aromatic hydrocarbons during pyrolysis of simulated municipal solid waste »

Analyst


Title:In situ calibration of micro-photoionization detectors in a multi-dimensional micro-gas chromatography system
Author(s):Lee J; Zhou M; Zhu H; Nidetz R; Kurabayashi K; Fan X;
Address:"Department of Biomedical Engineering, University of Michigan, 1101 Beal Avenue, Ann Arbor, Michigan 48109, USA. xsfan@umich.edu and Center for Wireless Integrated MicroSensing and Systems (WIMS2), University of Michigan, Ann Arbor, MI, 48109, USA. Center for Wireless Integrated MicroSensing and Systems (WIMS2), University of Michigan, Ann Arbor, MI, 48109, USA and Department of Mechanical Engineering, University of Michigan, 2350 Hayward, Ann Arbor, Michigan 48109, USA"
Journal Title:Analyst
Year:2016
Volume:141
Issue:13
Page Number:4100 - 4107
DOI: 10.1039/c6an00261g
ISSN/ISBN:1364-5528 (Electronic) 0003-2654 (Linking)
Abstract:"A photoionization detector (PID) is widely used as a gas chromatography (GC) detector. By virtue of its non-destructive nature, multiple PIDs can be used in multi-dimensional GC. However, different PIDs have different responsivities towards the same chemical compound with the same concentration or mass due to different aging conditions of the PID lamps and windows. Here, we carried out a systematic study regarding the response of 5 Krypton muPIDs in a 1 x 4-channel 2-dimensional muGC system to 7 different volatile organic compounds (VOCs) with the ionization potential ranging from 8.45 eV to 10.08 eV and the concentration ranging from approximately 1 ng to approximately 2000 ng. We used one of the PIDs as the reference detector and calculated the calibration factor for each of the remaining 4 PIDs against the first PID, which we found is quite uniform regardless of the analyte, its concentration, or chromatographic peak width. Based on the above observation, we were able to quantitatively reconstruct the coeluted peaks in the first dimension using the signal obtained with a PID array in the second dimension. Our work will enable rapid and in situ calibration of PIDs in a GC system using a single analyte at a single concentration. It will also lead to the development of multi-channel multi-dimensional GC where multiple PIDs are employed"
Keywords:
Notes:"PubMed-not-MEDLINELee, Jiwon Zhou, Menglian Zhu, Hongbo Nidetz, Robert Kurabayashi, Katsuo Fan, Xudong eng England 2016/05/07 Analyst. 2016 Jun 20; 141(13):4100-7. doi: 10.1039/c6an00261g"

 