Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractModeling of the Mass Spectrometric Response Factors in Non-target Analysis    Next AbstractHandheld two-stroke engines as an important source of personal VOC exposure for olive farm workers »

J Chromatogr A


Title:Calibration of mass selective detector in non-target analysis of volatile organic compounds in the air
Author(s):Arh G; Klasinc L; Veber M; Pompe M;
Address:"Faculty of Chemistry and Chemical Technology, University of Ljubljana, Askerceva 5, 1000 Ljubljana, Slovenia. gregor.arh@fkkt.uni-lj.si"
Journal Title:J Chromatogr A
Year:2011
Volume:20110119
Issue:11
Page Number:1538 - 1543
DOI: 10.1016/j.chroma.2011.01.037
ISSN/ISBN:1873-3778 (Electronic) 0021-9673 (Linking)
Abstract:"Volatile organic compounds (VOCs) play an important role in the chemistry of the atmosphere and in biogeochemistry. They contribute to the oxidative capacity of the atmosphere, particle and air pollutants, as well as to the production of greenhouse gases (for instance ozone). Among analytical techniques for their determination in the atmosphere gas chromatography coupled with mass spectrometry (GC-MS) offers several advantages. However, for an accurate quantification calibration with standard substances is necessary. A quantitative structure-property relationship (QSPR) model for the prediction of MS response factors was developed on basis of our experimental measurements for the quantification of ozone precursors present in the atmosphere. A linear correlation between chemical structures and response factors was established by using a 7-parameter MLR model. The average error in the prediction of response factors was calculated by cross-validation procedure and was below 20%, which is sufficient for the determination of VOCs in the air. The proposed procedure is time consuming so it is more suited for the quantification of tentatively identified organic compounds during the reprocessing of MS chromatograms in cases when the original sample is no longer available"
Keywords:"Air/*analysis Chromatography, Gas/*methods Gas Chromatography-Mass Spectrometry Volatile Organic Compounds/*analysis;"
Notes:"MedlineArh, Gregor Klasinc, Leo Veber, Marjan Pompe, Matevz eng Research Support, Non-U.S. Gov't Netherlands 2011/02/09 J Chromatogr A. 2011 Mar 18; 1218(11):1538-43. doi: 10.1016/j.chroma.2011.01.037. Epub 2011 Jan 19"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024