Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractChemical Characterization and Volatile Profile of Trebbiano di Lugana Wine: A Case Study    Next AbstractAvoidance of intraguild predation leads to a long-term positive trait-mediated indirect effect in an insect community »

Rev Port Pneumol


Title:Indoor air quality and respiratory symptoms in Porto schools
Author(s):Fraga S; Ramos E; Martins A; Samudio MJ; Silva G; Guedes J; Oliveira Fernandes E; Barros H;
Address:"Servico de Higiene e Epidemiologia da Faculdade de Medicina da Universidade do Porto, Hygiene and Epidemiology Unit, School of Medicine, Universidade do Porto"
Journal Title:Rev Port Pneumol
Year:2008
Volume:14
Issue:4
Page Number:487 - 507
DOI:
ISSN/ISBN:0873-2159 (Print) 0873-2159 (Linking)
Abstract:"AIM: To evaluate the association between the indoor air quality in Porto schools and the prevalence of allergic and respiratory symptoms in adolescents. MATERIAL AND METHODS: Temperature, relative humidity, carbon dioxide (CO2) and volatile organic compound (VOC) concentrations were evaluated in nine Porto schools. Questionnaires were distributed to 9 classes of 7th , 8th and 9th year students in each school, total 1607 adolescents, with a mean age of 14.0 years (standard deviation=0.3). Information was collected on participants' socio-demographic and social characteristics, behaviour, and housing conditions. The International Study of Asthma and Allergies in Childhood (ISAAC) questionnaire was used to evaluate respiratory symptoms. RESULTS: 5.8% of participants stated they had had asthma, 9.2% wheezing, 22.0% sneezing and 6.6% itchy rash In the 12 months preceding the evaluation. After adjustment for parental educational attainment level, CO2 > 2100 ppm values were associated with exercise- induced wheeze [OR=1.86 (95%CI:1.20-2.89)] and night cough [OR=1.40 (4.20-2.89)]. We observed an increasing odds ratio in wheezing symptoms over the last 12 months, in asthma 'at some point' and asthma over the last 12 months, and night cough at schools with higher VOC values. The association was not statistically significant, however. CONCLUSION: Lower indicators of indoor air quality, particularly CO2, were associated with a greater respiratory symptomatology"
Keywords:"Adolescent Air Pollution, Indoor/*analysis Child Female Humans Male Portugal Prevalence Respiration Disorders/*epidemiology;"
Notes:"MedlineFraga, Silvia Ramos, Elisabete Martins, Anabela Samudio, Maria Joao Silva, Gabriela Guedes, Joaquim Oliveira Fernandes, Eduardo Barros, Henrique eng por Research Support, Non-U.S. Gov't Spain 2008/07/16 Rev Port Pneumol. 2008 Jul-Aug; 14(4):487-507"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 22-11-2024