Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractKey aroma compounds of Canastra cheese: HS-SPME optimization assisted by olfactometry and chemometrics    Next AbstractAnalysis of Volatile Organic Compounds in Exhaled Breath Following a COMEX-30 Treatment Table »

Rapid Commun Mass Spectrom


Title:"Novel methods for the analysis of toxicants in bronchoalveolar lavage fluid samples from e-cigarette, or vaping, product use-associated lung injury cases: Selected petroleum distillates"
Author(s):De Jesus VR; Chambers DM; Reese C; Braselton M; Espinosa P; Corstvet J; Blount BC;
Address:"Tobacco and Volatiles Branch, Division of Laboratory Sciences, Centers for Disease Control and Prevention, Atlanta, GA, USA"
Journal Title:Rapid Commun Mass Spectrom
Year:2020
Volume:34
Issue:19
Page Number:e8898 -
DOI: 10.1002/rcm.8898
ISSN/ISBN:1097-0231 (Electronic) 0951-4198 (Print) 0951-4198 (Linking)
Abstract:"RATIONALE: Over 2700 e-cigarette, or vaping, product use-associated lung injury (EVALI) cases were reported to the Centers for Disease Control and Prevention (CDC) during August 2019-February 2020. Bronchoalveolar lavage (BAL) fluid samples from 51 EVALI and 99 non-EVALI cases were analyzed for toxicants including petroleum distillates. We describe a novel method to measure petroleum distillates in BAL fluid using gas chromatography-mass spectrometry (GC/MS). METHODS: n-Hexane, n-heptane, n-octane, methylcyclopentane, and cyclohexane were measured in BAL fluid specimens by headspace solid-phase microextraction/GC/MS. We created and characterized BAL fluid pools from non-EVALI individuals to determine assay accuracy, precision, linearity, limits of detection (LODs), and analytical specificity. All measurements were conducted in accordance with the rigorous method validation procedures of CDC's Division of Laboratory Sciences. RESULTS: Matrix validation experiments showed that calibration curves in BAL fluid and saline had similar slopes, with differences less than 5%. Assay precision ranged from 1.98% to 18%. In addition, the LODs for the five analytes ranged from 0.05 to 0.10 mug/L, and their linearity was confirmed with R(2) values >0.99. The analysis of selected petroleum distillates in BAL fluid analysis was shown to be comparable with their analysis in blood in which the 95th percentiles are below detection. CONCLUSIONS: We developed and validated a method to quantify petroleum distillates in BAL fluid specimens using GC/MS. The assay provided precise and accurate analyses of EVALI and non-EVALI BAL fluid specimens in support of CDC's EVALI response. This method is applicable to the determination of a broad range of volatile organic compounds in BAL fluid specimens"
Keywords:Bronchoalveolar Lavage Fluid/*chemistry Electronic Nicotine Delivery Systems Humans Limit of Detection Linear Models *Lung Injury/etiology/metabolism Petroleum/*analysis Reproducibility of Results Vaping/*adverse effects;
Notes:"MedlineDe Jesus, Victor R Chambers, David M Reese, Christopher Braselton, Martha Espinosa, Paul Corstvet, Joseph Blount, Benjamin C eng CC999999/ImCDC/Intramural CDC HHS/ England 2020/07/17 Rapid Commun Mass Spectrom. 2020 Oct 15; 34(19):e8898. doi: 10.1002/rcm.8898"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 22-11-2024