Title: | A Gas Chromatographic Continuous Emissions Monitoring System for the Determination of VOCs and HAPs |
Address: | "a Research Department, R. J. Reynolds Tobacco Company , Winston-Salem , NC" |
DOI: | 10.1080/10473289.1996.10467438 |
ISSN/ISBN: | 2162-2906 (Electronic) 1096-2247 (Linking) |
Abstract: | "This article describes a new gas chromatography-based emissions monitoring system for measuring volatile organic compounds (VOCs) and hazardous air pollutants (HAPs). The system is composed of a dual-column gas chromatograph equipped with thermal conductivity detectors, in which separation is optimized for fast chromatography. The system has the necessary valving for stream selection, which allows automatic calibration of the system at predetermined times and successive measurement of individual VOCs before and after a control device. Nine different VOCs (two of which are HAPs), plus methane (CH4) and carbon dioxide (CO2) are separated and quantified every two minutes. The accuracy and precision of this system has been demonstrated to be greater than 95%. The system employs a mass flow measurement device and also calculates and displays processed emission data, such as control device efficiency and total weight emitted during given time periods. Two such systems have been operational for one year in two separate gravure printing facilities; minimal upkeep is required, about one hour per month. One of these systems, used before and after a carbon adsorber, has been approved by the pertinent local permitting authority" |
Notes: | "PubMed-not-MEDLINEColeman, William M III Gordon, Bert M eng 1996/01/01 J Air Waste Manag Assoc. 1996 Jan; 46(1):30-34. doi: 10.1080/10473289.1996.10467438" |